Electra APE.1S1.x&x Installation Instructions Manual Download Page 5

page 5/6

4  insTallaTiOn seTup

4.1  verifying the accuracy of the connections and connecting the power supply

check the correctness of the connections in the installation!

The 

+14 V

C/D

 and 

GND

 signals are the same for all components of the installation. 

Any short-circuit between them will affect all the indoor terminals, causing them not to function.

connect the power supply to the 

230 V a.c.

 network through a 

10 A

 automated fuse!

Optionally, the accumulator is connected to the 

+ACC

;

-ACC

 hubs of the 

SAC.V1A.DIN

 power supply.

Pay attention to the connection to the correct polarity of the outdoor accumulator!

check the correct functioning of the power supply:

• 

The measured tension at the hubs of the power supply: 

+14 V

 

 

GND / 13,8 ÷ 14,3 V d.c.

•  Power supply signaling, according to the following table:

Signaling

Observations

Network tension

Tension presence: 

+14 V

+Uv

1

S1  permanent Green
S2  permanent Green

The installation is ready to function.

 

If the audio or video communication is not functioning, check the 

status of fuses Sig. 1 and Sig. 2 from the power supply.

230 V ± 10% 

50 Hz

+14 V

 

⟷ 

GND

 

13,8 ÷ 14,3 V d.c.

+Uv

 ⟷ 

-Uv

 

13,5 ÷ 15,0 V d.c.

2

S1  alternating Red / Green

S2  permanent Green

The installation is functioning.

Charging accumulator.

3

S1  alternating Red / Green

 

 

+ acoustic signaling

S2  permanent Green

The installation is functioning.

 

Faulty or uncharged accumulator: replace the accumulator!

4

S1  permanent/flashing Red

S2  turned off

The installation is functioning

 only on audio communication, 

for a limited amount of time.

 

Check the power fuse from the network and fuse Sig. 3.

NO: 

0 V

+14 V

 ⟷ 

GND

 

10,5 ÷ 13,8 V d.c.

+Uv

 ⟷ 

-Uv

 NO: 

0 V

5

S1  flashing Green

S2  turned off

The installation is NOT functioning.

 

Shortcircuit in the installation on 

+14 V

 and/or 

+Uv

.

Eliminate the shortcircuit and re-establish the connection!

230 V ± 10% 

50 Hz

NO: 

0 V

4.2  programming the Tags

The Red Programming TAG contains the unique code of the installation company.

When an outdoor panel reads a Programming TAG for the first time, it is personalized with the company’s unique code.

The code is permanently registered in the panel’s memory and can only be erased at the producer.

The personalized panel will not accept the Programming TAGs of other installation companies.

how to program the Tags’ access codes in the memory of the outdoor panel: 

The door on which the lock is mounted will remain closed the entire time it takes to program the TAGs! Entering the programming mode with the 
door open will erase all acces codes.

1. Use the Red Programming TAG!

  The panel enters the Programming Mode: [

BEEP

 

BEEP

 

BEEEEEEP

]

The Programming mode closes 

automatically

 if the panel is idle for more than 10 seconds or 

imediately

 by using the Programming TAG once more.

2. You now have a maximum of 10 sec. for each Access TAG.

  You will hear the following sounds:

• 

[

BEEP

 

BEEP

] when the Access Code has been succesfully memorized,

• 

[

BEEP

 

BEEP

] when the TAG’s Access Code is already in the panel’s memory,

• 

[

BEEP

] when the panel has been idle for 10 seconds and is no longer in the Programming Mode.

To erase all the access codes from the panel’s memory:

This action cannot be undone! The panel will not recognize any Access TAG.

1. Enter the Programming Mode!

 (by using the Programming TAG)

2. 

Operate the lock’s button

*

 for at least 6 seconds!

 Acoustic confirmation: [

BEEP

 

BEEP

 

BEEP

]

*

If the lock does not have a button, you need to short-circuit between the BUT and LC hubs (of the outdoor panel) for at least 6 seconds.

4.3  programming the address of the additional outdoor panel

Remember:

The default address of all oudoor panels is 1.
The installation must have one outdoor panel with the adress 1. This will be the main panel.
The outdoor panels must have unique addresses within the installation.

The installation does not work if 2 panel’s share the same address!

how to program the additional outdoor panel:

The door on which the lock is mounted will remain closed the entire time it takes to program the additional panel!

1. Use the Red Programming TAG on the additional panel!

  The panel enters the Programming Mode: [

BEEP

 

BEEP

 

BEEEEEEP

]

The Programming mode closes 

automatically

 if the panel is idle for more than 10 seconds or 

imediately

 by using the Programming TAG once more.

2. Press any key!

 [

BEEP

] when the panel’s address increases by +1, [

BEEP

 

BEEP

 

BEEP

] when the panel is bak to having address 1.

For the following 10 seconds, the additional panel is still in the Programming Mode and you may proceed to program its Access TAGs.