background image

 

 

G

G

B

B

 

 

 

 

W

W

i

i

r

r

e

e

l

l

e

e

s

s

s

s

 

 

I

I

n

n

d

d

o

o

o

o

r

r

 

 

S

S

i

i

r

r

e

e

n

n

 

 

(

(

S

S

R

R

A

A

-

-

8

8

)

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BACK VIEW 

 

 

INSIDE VIEW

 

 

1. 

Battery Compartment  

                                                                                                     

 (with a lid secured with 4 screws)

 

2. 

Function Dip Switch 

 

Contains 7 dip switches to enable the learning mode and to set the alarm period of siren. 

3. 

Tampe

 

r

4. 

Buzzer

 

hole

 

5. 

4 Mounting holes

 

 

                                                                                                             

Accessories included 

In addition to the SRA-8 itself, the following accessories are also included in the package: 

a. 4 x D-cell Alkaline Batteries to be placed in  
b. 4 x 6mm dowels. 
c. 4 x screws to be placed in four corners 

D

D

i

i

p

p

 

 

S

S

w

w

i

i

t

t

c

c

h

h

 

 

P

P

o

o

s

s

i

i

t

t

i

i

o

o

n

n

 

 

T

T

a

a

b

b

l

l

e

e

 

 

You can find dip switches marked 1-7 from left to right. The function of each dip switch is stated in the table below. 

 

2

Dip 1 

 

 

 ON 

Learning 

Mode 

 OFF 

Normal 

Mode 

Dip 3 

Dip 4 

Alarm Period 

ON OFF 

min 

OFF ON 90 

sec. 

OFF OFF 

min. 

ON ON 

sec. 

Dip 6 

 

 

 ON 

Clear 

Memory 

 OFF 

Normal 

 
 

 

 

 

 

 

 

 

 

 

*

*

d

d

i

i

p

p

 

 

s

s

w

w

i

i

t

t

c

c

h

h

 

 

2

2

,

,

 

 

5

5

,

,

 

 

a

a

n

n

d

d

 

 

7

7

 

 

i

i

s

s

 

 

p

p

r

r

e

e

s

s

e

e

t

t

.

.

 

 

S

S

R

R

A

A

-

-

8

8

 

 

F

F

u

u

n

n

c

c

t

t

i

i

o

o

n

n

 

 

O

O

v

v

e

e

r

r

v

v

i

i

e

e

w

w

 

 

 

 

S

S

i

i

r

r

e

e

n

n

 

 

M

M

e

e

m

m

o

o

r

r

y

y

 

 

C

C

l

l

e

e

a

a

r

r

 

 

The siren can be reset and the memory contents cleared by removing the batteries, waiting for 1 minute, sliding dip 
switch 6 to ON position and then re-inserting the batteries.   The siren will produce a short confirmation tone. Dip switch 
should then be slid to OFF position otherwise the siren code learning will be reset every time the siren has a power-up 
sequence. 
 
 

Summary of Contents for SRA-8

Page 1: ...S SR RA A 8 8 O OW WN NE ER R S S M MA AN NU UA AL L A Ar rt t 3 36 6 2 28 86 69 9 1...

Page 2: ...dip switches marked 1 7 from left to right The function of each dip switch is stated in the table below 2 Dip 1 ON Learning Mode OFF Normal Mode Dip 3 Dip 4 Alarm Period ON OFF 5 min OFF ON 90 sec OF...

Page 3: ...nf fi ir rm m O On n C Co on nf fi ir rm m O Of ff f The siren can be programmed to produce additional confirmation beeps to tell you when the system is armed disarmed and low in battery The setting...

Page 4: ...ive a long beep to confirm followed by the siren s response of two short beeps If the Siren has been already learnt in then one short beep will performed to notify the user Step 5 Slide dip switch 1 t...

Page 5: ...iften som r markerade 1 7 fr n v nster till h ger Funktionen p varje stift beskrivs i tabellen h r nedan 5 Stift 1 P Test L ge AV Normalt L ge Stift 3 Stift 4 Larm Period P AV 5 min AV P 90 sek AV AV...

Page 6: ...siren P och Intr ng siren AV F r att bekr fta tryck OK B Be ek kr r f ft te el ls se e P P b be ek kr r f ft te el ls se e A Av v Sirenen kan programmeras till att s nda ut bekr ftelsesignaler detta...

Page 7: ...mmera siren och sedan Testa siren Steg 4 Tryck OK och kontrollenheten ger ifr n sig en l ng bekr ftelsesignal som f ljs av sirenens tv korta signaler Om sirenen redan har blivit testad d kommer en kor...

Page 8: ...m mi ie en n a as se et tu uk ks se et t Jokaisen DIP kytkimen toiminto n kyy alla olevasta taulukosta 8 Dip 1 ON p ll Opetustila OFF pois p lt Normaalitila Dip 3 Dip 4 H lytysaika ON OFF 5 min OFF ON...

Page 9: ...assa Laitteen murtosuoja voidaan laittaa p lle tai pois p lt ohjauspaneelin kautta Valitse paneelin Device valikosta Program Siren ja valitse Siren Tamp ON tai Siren Tamp OFF Vahvista valinta painamal...

Page 10: ...veja liian tiukasti S SR RA A 8 8 o oh hj je el lm mo oi in nt ti i Tiedotus Muista lis t ainakin joku toinen laite ohjauspaneeliin ennen kuin lis t SRA 8 Askel 1 Paikallista DIP kytkimet Askel 2 Siir...

Page 11: ...and ceilings Frequency 868 MHz Dimensions 228mm L 113mm W 54mm H Art nr 36 2869 DECLARATION OF CONFORMITY Hereby Electia AB declares that the SRA 8 is in compliance with the essential requirements and...

Page 12: ...421 30 V stra Fr lunda Sweden www electia se 12...

Reviews: