background image

 

4

 

 

P

P

o

o

w

w

e

e

r

r

 

 

S

S

u

u

p

p

p

p

l

l

y

y

 

 

SRA-8 features completely wire-free operation and uses four alkaline D cells. The battery-life is estimated for 3 years. 

The SRA-8 can detect if the battery is low. Low battery detection operates at a threshold of 4.4V +/- 10% where the 
SRA-8 has enough power to typically operate for 1 month before complete exhaustion. The siren low battery signal will 
be enunciated by five beeps under Operation Mode.  

On the other hand, during an alarming period low battery status, the siren sound will be incomplete. For Burglary, Fire 
and water alarm duration, SRA-8 gives an Intermittent alarm sound of 500 ms, 460 ms and 460 ms ~ 1400 ms of 
cyclical accordingly.  

G

G

e

e

t

t

t

t

i

i

n

n

g

g

 

 

S

S

t

t

a

a

r

r

t

t

e

e

d

d

 

 

 

 

To insert the batteries:   
Step 1. 

Release the screws at the bottom of SRA-8 and pull the outer case out carefully.   

Step 2. 

The battery compartment is a large box in the SRA-8 with a lid secured with 4 screws. 

Step 3. 

Remove the four screws as shown and take off the compartment lid. 

Step 4. 

Insert the D cell alkaline batteries provided into the battery compartment, taking care to put 
the batteries in the right way around. 

Step 5. 

The siren will give a short confirmation tone when the last battery is inserted. 

Step 6. 

Replace the battery compartment lid with the four screws taking care not to over tighten 

P

P

r

r

o

o

g

g

r

r

a

a

m

m

m

m

i

i

n

n

g

g

 

 

S

S

R

R

A

A

-

-

8

8

 

 

 

 

 

 

Note:  Remember to learn in at least one other device into control panel before SRA-8 can be added  
Step 1. 

Locate dip switches. 

Step 2. 

Slide dip switch 1 to ON. The siren will give two short beeps to indicate it is now in the learn mode. 

Step 3. 

Program the control unit by selecting “

/-

“ menu, then “

Program Siren

” menu, then “

Learn Siren

”. 

Step 4. 

Press OK and the control unit will give a long beep to confirm, followed by the siren’s response of two short 
beeps. If the Siren has been already learnt-in, then, one short beep will performed to notify the user. 

Step 5. 

Slide dip switch 1 to OFF position, the siren will give one short beep to confirm that the siren is now in Normal 
Operation mode. 

Step 6. 

Select “

Confirm ON

” or “

Confirm OFF

” under the “

Program Siren

” menu on the control unit, and press “

OK

”. 

The siren will perform one short beep to notify the user. 

Step 7. 

Select “

Entry Sound ON

” or “

Entry Sound OFF

” under the  “

Program Siren

” menu on the control unit, and 

press “

OK

”. The siren will perform one short beep to notify the user. 

Step 8. 

Set dip switch 3 and 4 for your desired alarm period.  

Step 9. 

The Learn-in process is now completed. 

<

<

N

N

O

O

T

T

E

E

>

>

 

 

 

 

For Step 4, 6 and 7, please wait for 6 seconds after press the “

OK

” button each time. 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

i

i

n

n

g

g

 

 

S

S

R

R

A

A

-

-

8

8

 

 

 

 

Step 1. 

Find the location where SRA-8 is to be mounted 

Step 2. 

Using the 4 holes on the back of the base as shown as a template, mark off the holes’ 
positions. 

Step 3. 

Drill 4 holes and using the wall plugs and screws provided fix to a suitable wall. 

Step 4. 

Close the lid and tighten the lid fixing screw. 

Step 5. 

Enable Tamper switch by selecting “

Siren Tamp ON

” under the  “

Program Siren

” menu 

on the control unit 

Step 6. 

Installation is now completed. 

 

 

C

C

h

h

a

a

n

n

g

g

i

i

n

n

g

g

 

 

t

t

h

h

e

e

 

 

B

B

a

a

t

t

t

t

e

e

r

r

y

y

 

 

Whenever low battery enunciation arises and it is time for you to replace the batteries, remember to first disable the 
Tamper Protection from the Control Panel by selecting “

/-

“ menu, then “

Program Siren

” menu, then “

Siren 

Tamp. OFF

” and press OK. 

When changing the batteries, please wait for one minute before inserting the new battery in. After the batteries have been 
replaced, remember to enable the Tamper Switch again. Or the Disabled Tamper Switch will automatically revert to ON 
after about an hour if not switched back on again manually by selecting “

Siren Tamp. On

”. 

 
 
 
 

Summary of Contents for SRA-8

Page 1: ...S SR RA A 8 8 O OW WN NE ER R S S M MA AN NU UA AL L A Ar rt t 3 36 6 2 28 86 69 9 1...

Page 2: ...dip switches marked 1 7 from left to right The function of each dip switch is stated in the table below 2 Dip 1 ON Learning Mode OFF Normal Mode Dip 3 Dip 4 Alarm Period ON OFF 5 min OFF ON 90 sec OF...

Page 3: ...nf fi ir rm m O On n C Co on nf fi ir rm m O Of ff f The siren can be programmed to produce additional confirmation beeps to tell you when the system is armed disarmed and low in battery The setting...

Page 4: ...ive a long beep to confirm followed by the siren s response of two short beeps If the Siren has been already learnt in then one short beep will performed to notify the user Step 5 Slide dip switch 1 t...

Page 5: ...iften som r markerade 1 7 fr n v nster till h ger Funktionen p varje stift beskrivs i tabellen h r nedan 5 Stift 1 P Test L ge AV Normalt L ge Stift 3 Stift 4 Larm Period P AV 5 min AV P 90 sek AV AV...

Page 6: ...siren P och Intr ng siren AV F r att bekr fta tryck OK B Be ek kr r f ft te el ls se e P P b be ek kr r f ft te el ls se e A Av v Sirenen kan programmeras till att s nda ut bekr ftelsesignaler detta...

Page 7: ...mmera siren och sedan Testa siren Steg 4 Tryck OK och kontrollenheten ger ifr n sig en l ng bekr ftelsesignal som f ljs av sirenens tv korta signaler Om sirenen redan har blivit testad d kommer en kor...

Page 8: ...m mi ie en n a as se et tu uk ks se et t Jokaisen DIP kytkimen toiminto n kyy alla olevasta taulukosta 8 Dip 1 ON p ll Opetustila OFF pois p lt Normaalitila Dip 3 Dip 4 H lytysaika ON OFF 5 min OFF ON...

Page 9: ...assa Laitteen murtosuoja voidaan laittaa p lle tai pois p lt ohjauspaneelin kautta Valitse paneelin Device valikosta Program Siren ja valitse Siren Tamp ON tai Siren Tamp OFF Vahvista valinta painamal...

Page 10: ...veja liian tiukasti S SR RA A 8 8 o oh hj je el lm mo oi in nt ti i Tiedotus Muista lis t ainakin joku toinen laite ohjauspaneeliin ennen kuin lis t SRA 8 Askel 1 Paikallista DIP kytkimet Askel 2 Siir...

Page 11: ...and ceilings Frequency 868 MHz Dimensions 228mm L 113mm W 54mm H Art nr 36 2869 DECLARATION OF CONFORMITY Hereby Electia AB declares that the SRA 8 is in compliance with the essential requirements and...

Page 12: ...421 30 V stra Fr lunda Sweden www electia se 12...

Reviews: