Heater will not switch to HEATER ON mode 

 

In most cases this will be the result of one of the following not being met. 
 
Possible Cause 1.)  The required temperature has been achieved.  
To confirm that the digital controller is requesting the unit to heat check that the window next to 
the word HEAT is illuminated. If illuminated go to step 2, if not illuminated increase the required 
temperature to a value higher than the current water temperature. Confirm whether the heater 
now switches to HEATER ON mode 

T

ROUBLE

 S

HOOTING

 

Possible Cause 2.)  The high limiting thermostat has tripped. 
Remedy; remove button cover and press red button to re-set (See diagram below). If a positive 
click is felt, the cause of the tripping 

must

 be investigated and could be caused by a debris build 

up or air pocket trapped inside the flow tube of the heater.  

Step 2 

- Push the red button 

Step 1 

- Unscrew the black cover 

Possible Cause 3.) Insufficient Flow. 
The heater will display a noFL alarm message in the upper (red) display window when the heater 
has detected that the flow rate has dropped below 1,000-litres per hour or has stopped  
completely.  

HEAT = If Continuously Illuminated 

Indicates that the water temperature has fallen  
below the required temperature. 

HEAT = If Flashing 

Indicates that the heater is in timed delay mode (see 
previous page). 

PRIORITY HEATING 

REQUIRED  

TEMP 

Summary of Contents for In-Line + Swimming Pool Heater

Page 1: ...LEASE READ CAREFULLY BEFORE INSTALLING Do Not Discard Keep For Future Reference Incorrect Installation Will Affect Your Warranty In Line Swimming Pool Heater Installation Instructions Operating Manual...

Page 2: ...er in this booklet the heater MUST remain sited after the filter Only clean filtered water should enter the heater It is essential that the pipe work connecting to and from the heater has a minimum bo...

Page 3: ...The power supply must be fitted with a RCD If required your electrician may replace the supplied cable entry gland with a larger one to secure the cable powering the heater this will not affect your w...

Page 4: ...ht this can be reversed by rotating the flow switch 180 i e turn see diagram below The flow rate of water entering the heater must not exceed 17 000 litres per hour 3 740 UK gallons per hour A higher...

Page 5: ...Heating The actual pool temperature is displayed in the red upper display The lower green display required temperature can be selected by the user This is the temperature you would like your pool wat...

Page 6: ...nterlock cable directly to the swimming pool pump as this will result in overloading the heaters digital controller TIME SWITCHING DELAY To prevent overheating of the switch components within the heat...

Page 7: ...ripped Remedy remove button cover and press red button to re set See diagram below If a positive click is felt the cause of the tripping must be investigated and could be caused by a debris build up o...

Page 8: ...kW in a one hour period The conclusion of the test should prove that for example a 6 kW heater and a horsepower pump will draw between 6 3 kW to 6 5 kW in one hour It is impossible for an electric he...

Page 9: ...influencing factors are the level of insulation and the sighting of the pool with regard to wind shelter Useful advice To reduce running costs and speed up the heating process Insulate the pool where...

Page 10: ...he harmonised standards have been applied EN 60335 2 35 Elecro Engineering Limited Unit 11 Gunnels Wood Park Stevenage Hertfordshire SG1 2BH UK Tel 44 0 1438 749 474 Fax 44 0 1438 361 329 Website www...

Reviews: