The digital controller fitted to the In-Line + heater has been pre-programmed with all the  
necessary parameters to ensure reliable service & operation. Below is a key explaining the  
controllers buttons & LED signals however these will all be explained in detail later in this  
booklet. 

Press and hold for 2 seconds to power the control on / off. 
 
 
Press to increase required pool temperature. 
 
 
Press to decrease required pool temperature. 
 
 
Press and release to activate / deactivate ‘Priority of Heating’. 

The actual pool temperature is displayed in the red upper display. The lower green display 
‘required temperature’ can be selected by the user. This is the temperature you would like your 
pool water to be maintained at. 
Priority of Heating is a function that ensures your pool water is constantly maintained at your  
required temperature. When Priority of heating is activated the Priority of Heating Icon on the 
bottom right of the display will illuminate. The control will now monitor the pool temperature, 
and start both the pool circulation pump and heating process when necessary - please see pump 
interlock section for details on how to connect the pump interlock cable. 

When illuminated 

unit is heating 

Summary of Contents for In-Line + Swimming Pool Heater

Page 1: ...LEASE READ CAREFULLY BEFORE INSTALLING Do Not Discard Keep For Future Reference Incorrect Installation Will Affect Your Warranty In Line Swimming Pool Heater Installation Instructions Operating Manual...

Page 2: ...er in this booklet the heater MUST remain sited after the filter Only clean filtered water should enter the heater It is essential that the pipe work connecting to and from the heater has a minimum bo...

Page 3: ...The power supply must be fitted with a RCD If required your electrician may replace the supplied cable entry gland with a larger one to secure the cable powering the heater this will not affect your w...

Page 4: ...ht this can be reversed by rotating the flow switch 180 i e turn see diagram below The flow rate of water entering the heater must not exceed 17 000 litres per hour 3 740 UK gallons per hour A higher...

Page 5: ...Heating The actual pool temperature is displayed in the red upper display The lower green display required temperature can be selected by the user This is the temperature you would like your pool wat...

Page 6: ...nterlock cable directly to the swimming pool pump as this will result in overloading the heaters digital controller TIME SWITCHING DELAY To prevent overheating of the switch components within the heat...

Page 7: ...ripped Remedy remove button cover and press red button to re set See diagram below If a positive click is felt the cause of the tripping must be investigated and could be caused by a debris build up o...

Page 8: ...kW in a one hour period The conclusion of the test should prove that for example a 6 kW heater and a horsepower pump will draw between 6 3 kW to 6 5 kW in one hour It is impossible for an electric he...

Page 9: ...influencing factors are the level of insulation and the sighting of the pool with regard to wind shelter Useful advice To reduce running costs and speed up the heating process Insulate the pool where...

Page 10: ...he harmonised standards have been applied EN 60335 2 35 Elecro Engineering Limited Unit 11 Gunnels Wood Park Stevenage Hertfordshire SG1 2BH UK Tel 44 0 1438 749 474 Fax 44 0 1438 361 329 Website www...