The heater should be installed within a dry weatherproof enclosure.  

CAUTION 

If the heater is not used during winter months it must be drained to prevent frost damage. 

Upon completion of the installation, run the water-circulating pump to purge the system & heater 
of air (i.e. remove any trapped air in the system & heater).  

The heater must be installed in accordance with the country / regional requirements &  
regulations. In any event the work must be carried out by a qualified electrician, who will  
provide a certificate of conformity upon completion of the work.  
The power supply 

must

 be fitted with a RCD. If required your electrician may replace the  

supplied cable entry gland with a larger one to secure the cable powering the heater, this will not 
affect your warranty if carried out by a qualified electrician. 
Cable section: should be calculated at 5-amp / mm² for distances up to 20 metres (these sections 
are indicative and should be checked and adapted if necessary for cable lengths over 20 metres). 

P

OWER

 R

EQUIREMENTS

 

Power Output 

Volt (V) 

Amp 

2-kW 

230 

3-kW 

230 

13 

4.5-kW 

230 

20 

6-kW 

230 

27 

9-kW 

230 

40 

12-kW 

230 

53 

15-kW 

230 

66 

18-kW 

230 

79

 

E

LECTRICAL

 C

ONNECTION

 

3 Phase 

Power 

Output 

400V 

Star / 

230V 

Delta 

Amp 

6-kW 

400V / 230V 

9 / 15 

9-kW 

400V / 230V 

13 / 23 

12-kW 

400V / 230V 

18 / 31 

15-kW 

400V / 230V 

22 / 38 

18-kW 

400V / 230V 

26 / 46 

24-kW 

400V 

35 

Summary of Contents for In-Line + Swimming Pool Heater

Page 1: ...LEASE READ CAREFULLY BEFORE INSTALLING Do Not Discard Keep For Future Reference Incorrect Installation Will Affect Your Warranty In Line Swimming Pool Heater Installation Instructions Operating Manual...

Page 2: ...er in this booklet the heater MUST remain sited after the filter Only clean filtered water should enter the heater It is essential that the pipe work connecting to and from the heater has a minimum bo...

Page 3: ...The power supply must be fitted with a RCD If required your electrician may replace the supplied cable entry gland with a larger one to secure the cable powering the heater this will not affect your w...

Page 4: ...ht this can be reversed by rotating the flow switch 180 i e turn see diagram below The flow rate of water entering the heater must not exceed 17 000 litres per hour 3 740 UK gallons per hour A higher...

Page 5: ...Heating The actual pool temperature is displayed in the red upper display The lower green display required temperature can be selected by the user This is the temperature you would like your pool wat...

Page 6: ...nterlock cable directly to the swimming pool pump as this will result in overloading the heaters digital controller TIME SWITCHING DELAY To prevent overheating of the switch components within the heat...

Page 7: ...ripped Remedy remove button cover and press red button to re set See diagram below If a positive click is felt the cause of the tripping must be investigated and could be caused by a debris build up o...

Page 8: ...kW in a one hour period The conclusion of the test should prove that for example a 6 kW heater and a horsepower pump will draw between 6 3 kW to 6 5 kW in one hour It is impossible for an electric he...

Page 9: ...influencing factors are the level of insulation and the sighting of the pool with regard to wind shelter Useful advice To reduce running costs and speed up the heating process Insulate the pool where...

Page 10: ...he harmonised standards have been applied EN 60335 2 35 Elecro Engineering Limited Unit 11 Gunnels Wood Park Stevenage Hertfordshire SG1 2BH UK Tel 44 0 1438 749 474 Fax 44 0 1438 361 329 Website www...