www.elecro.co.uk
23
Wipe a little silicone grease or Vaseline (not silicone sealant) onto these
threads. As these threads are only serviced periodically, this lubrication will
help to prevent them binding together. Then refit and firmly hand tighten
the compression fittings. Refit or replace the UV lamp(s) with a new one.
Relocate the lamp holders and blue lamp holder shrouds ensuring that
you match the correctly numbered lamp holder.
Note: Pinch the blue lamp holder shroud as you reassemble the unit to
release any trapped air. Failure to release the trapped air may cause the
lamp holder to disconnect from the lamp end. Reconnect and turn on the
water supply to check for leaks before reconnecting the electric supply.
Important: The plastic body and blue compression fittings have been
manufactured from polymers that have been specifically stabilised to
protect them from the effects of the UVC emitted from the UV lamps.
Despite this UV protection they will be eroded by a combination of the
UVC and water flow. As a matter of course they should be inspected
whenever a lamp change is carried out, to ensure they are not showing
excessive wear and tear. Replacement parts are available.
ENGL
IS
H
Summary of Contents for HR-110
Page 1: ...H R UV C Installation Operating Manual HR 55 HRP 55 HR 110 HRP 110...
Page 4: ...www elecro co uk 1 ENGLISH Fig 2 110W Double Tube Unit 3 Note Digital Model Shown...
Page 7: ...2 www elecro co uk ENGLISH Washer x4 Screw x4 Raw plug x5 Fig 5 6 55W Single Tube Unit...
Page 8: ...www elecro co uk 2 Fig 6 7 110W Double Tube Unit Washer x5 Raw plug x5 Screw x5...
Page 13: ...2 www elecro co uk ENGLISH 12 Fig 9 LAMP LIFE INDICATOR RESET SWITCH...
Page 30: ......
Page 31: ......