8
The digital display will show
‘NORMAL’
and the
graphical red coloured thermometer will be
‘Animated’ whenever the heating device is
switched
‘ON’
.
The actual pool water temperature is shown in the upper area of the display. The required temperature is
shown in the lower area of the display. The required water temperature can be adjusted by touching the
‘UP / DOWN’
touch button keys until the required temperature is displayed, adjustments are in 0.1°C
increments.
Priority of Heating is a function that ensures your pool water is constantly maintained at your required
temperature. When Priority of Heating is activated the Symbol
will be displayed on the screen.
The controller will then monitor the pool water temperature and start both the pool circulation pump and
heating process when necessary.
Time Switching Delay
To prevent overheating of the switch components within the heating device caused by frequent on/ off
switching (cycling) the controller has been pre-programmed with a time delay function.
When time switching delay is activated the message display will show ‘
HEATER DELAY’
for 2 minutes.
Differential
When the pool water has reached the required temperature the heating device will switch off and
will not switch back on until the water temperature has fallen 0.6°C below the required
temperature
.
Operating Modes
There are five operating modes:
Normal
Timer
Priority
Installation
Standby