11
Carefully remove the blue lamp holder shroud
and
white plastic electrical end caps from the
lamp end
Gently slide the lamp out ensuring that no
pressure is applied to the glass quartz
sleeve.
Unscrew the blue quartz sleeve locking nut
anticlockwise. Both ends must be unscrewed
before the quartz sleeve can be removed.
Slide the O-ring off the quartz sleeve
The quartz sleeve can now be removed.
Cleaning the quartz sleeve
Clean the sleeve and polish with a soft cloth or paper towel.
If you live in a hard water area there may be some limescale on the quartz sleeve. This can be easily
removed by soaking the sleeve in a proprietary kettle descaling solution (follow the manuf
acturer’s
instructions).
NOTE: Failure to remove the limescale will limit the effectiveness of the UV lamp(s).