SET/RESP format:
CPnnn; where nnn is 000-030. Applies only to SSB modes.
CW
(CW Pitch)
SET/RESP format:
CWnn; where nn is sidetone pitch x10 Hz (25-95).
DB$
(Audio dBV meter read)
RESP format:
DB$snnnn; where s is +/- and nnnn is 0-9999, representing audio signal
level for the main or sub RX ($) in 10ths of a dB. Useful for MDS measurements (see
Elecraft XG3 user manual for method).
SET format:
DB$0; (sets new 0 dB reference level for target receiver).
NOTE:
Even though measured dB values are independent of the AF GAIN setting, AGC
must be turned off to make the dBV reading accurate for signals above AGC threshold.
Use
GT
to turn off AGC. Use
AL
to limit audio signal strength when AGC is off.
DE
(Command Processing Delay; SET only)
SET format:
DEnnn where n can be 001 to 999 (ms * 10), i.e. up to 9.99 seconds (TBD).
DM
(DTMF; SET only)
SET format:
DMn where n = 0-9, A-D, *, or #. Applies to FM mode only.
DN
/
DNB
(VFO Move Down; SET only)
SET format:
DN; (move VFO A down one unit, based on the current VFO step size) or
DNB; (same for VFO B). Also see
UP
/
UPB
and
RU
/
RD
(RIT offset up/down).
TBD: Support for K3 variants.
DR$
(Data Rate) [Pending]
SET/RESP format:
DR$r; where <r> is the baud rate identifier:
AFSK-A, FSK-D: 0=45 baud, 1=75 baud; PSK-D: 0=31 baud, 1=63 baud.
DT$
(Data Sub-Mode)
SET/RESP format:
DT$n; where n is the data sub-mode set or last used, whether or not
DATA mode is in effect: 0 (DATA A), 1 (AFSK A), 2 (FSK D), or 3 (PSK D).