![Eldes ELAN3-SNMP User Manual Download Page 9](http://html1.mh-extra.com/html/eldes/elan3-snmp/elan3-snmp_user-manual_2377675009.webp)
99
EN
ELAN3
SNMP Ethernet Controller
4. GENERAL OPERATIONAL DESCRIPTION
ELAN3-SNMP SNMP Ethernet controller uses the Ethernet interface for connection to the Internet and event transmission by trap mes-
sage to up to 3 preset destination IP addresses.
The device has 4 inputs (customizable as digital or analog) for alarm system’s PGM output or detection device connection, such as
magnetic door contact. By connecting the device’s input to the output of the equipment, you will be able to receive a trap message to
the SNMP Manager software regarding equipment status and other events depending on equipment configuration. In addition to being
informed by trap message regarding input alarm and restore events as well as input voltage value (mV), the user can control up to two
electrical appliances by connecting them to the open-collector outputs. For example, users can turn ON or OFF the heating, lighting, lift
the gates, blinds etc.
ELAN3-SNMP can be equipped with up to 8 external temperature sensors for temperature monitoring in different areas.
5. CONFIGURATION, CONTROL AND MONITORING METHODS
5.1. Web Browser
The device comes equipped with remote access feature allowing to configure, control and monitor by logging in to the internal ELAN3-SN-
MP device’s web server, identified as ELAN Configuration Web Server, using any available web-browser.
NOTE:
ELAN Configuration Web Server is username/password-protected. By default, the login details are the following: User name:
1234
| password:
1234
5.1.1. Network
This section is intended for network configuration. In order to avoid the IP address collision in your local area network, once the
ELAN3-SNMP device is powered up for the first time it is mandatory to change the default LAN IP Address if DHCP server is not supported
by your network.
6
LAN IP Address
– Local static IP address of the device. Default value is
192.168.3.155
, if DHCP not in use.
LAN Net Mask
– Sub-net mask of the device. Default value is
255.255.255.0
, if DHCP not in use.
Default Gateway
– Local IP address of gateway. Default value is
192.168.3.1
, if DHCP not in use.
Primary DNS Server
– Primary Domain-Name-device server IP address. Default value is
194.25.2.129
, if DHCP not in use. This parameter
is mandatory if
Web Server
URL is used.
Secondary DNS Server
– Secondary Domain-Name-device server IP address.. Default value is
0.0.0.0
, if DHCP not in use.
Web Server URL
– Hostname of the device. Default value is eldeselan.
MAC Address
– Unique Media-Access-Control address of ELAN3-SNMP device.
Local Web Server Port
– Local TCP port of ELAN3-SNMP device. Default value is
80
.
DHCP
– Dynamic-Host-Configuration-Protocol:
•
ON
– DHCP enabled. Default parameter.
•
OFF
– DHCP disabled.
Save button
– Saves the changes made to the parameters in this page.
Undo button
– Cancels the changes made to the parameters in this page.
NOTE:
Some networks do not support DHCP. Please, contact your network administrator in order to find out whether DHCP is supported.