2.2.  Main Unit, LED Indicator & Connector Functionality

1

FRONT SIDE

SIDE VIEW

USB

LAN 

(green)

LAN 

(yellow)

USB

RJ45

DEF

F1

AC/DC

C1 COM

Z2  Z1 +5V DATA

Z3

C2/

Z4

STATUS

RJ45

RJ45

10/100Base-T Ethernet port

USB

Mini USB port for firmware update

DEF

Pins for firmware update and restoring default parameters

STATUS

Red light-emitting diode indicating micro-controller status

F1

miniSMDC 0,5A fuse

AC/DC

Power supply terminals

C1

Open-collector output terminal

COM

Common terminal

C2/Z4

Open-collector output | digital/analog input terminal

Z3, Z2, Z1

Digital/analog input terminal

+5V

Temperature sensor power supply terminal

DATA

Temperature sensor data terminal

LAN (green)

Green light-emitting diode indicating Ethernet activity

LAN (yellow)

Yellow light-emitting diode indicating Ethernet status

Summary of Contents for ELAN3-SNMP

Page 1: ...ELAN3 SNMP SNMP ETHERNET CONTROLLER...

Page 2: ...SB cable Null PE ELAN3 AC DC Disconnect the mains power before installing Never install or carry out maintenance during stormy weather The electric socket that powers the device must be easily accessi...

Page 3: ...onnector Functionality 6 2 3 Wiring Diagrams 7 3 INSTALLATION 8 4 GENERAL OPERATIONAL DESCRIPTION 9 5 CONFIGURATION CONTROL AND MONITORING METHODS 9 5 1 Web Browser 9 The following section is intended...

Page 4: ...d following all guidelines outlined in this manual and in accordance with the operat ing conditions specified The warranty is void if the device has been exposed to mechanical impact chemicals high hu...

Page 5: ...n collector output or 3 inputs and 2 open collector outputs Inputs customizable as NC or NO Supported input modes digital or analog 1 Wire interface for up to 8 temperature sensor connection intended...

Page 6: ...toring default parameters STATUS Red light emitting diode indicating micro controller status F1 miniSMDC 0 5A fuse AC DC Power supply terminals C1 Open collector output terminal COM Common terminal C2...

Page 7: ...ng 2 12V 0 10V 0 10V AC DC C1 COM Z2 Z1 5V DATA Z3 C2 Z4 Temperature sensor wiring 5V 5V DATA DATA GND GND FRONT AC DC C1 COM Z2 Z1 5V DATA Z3 C2 Z4 3 Example of output wiring 4 Alarm system or other...

Page 8: ...le indicator LAN yellow will be steady ON indicating successful Ethernet connection see Fig No 1 6 Once the device is up and running it will automatically obtain a local IP address from the DHCP serve...

Page 9: ...ation Web Server is username password protected By default the login details are the following User name 1234 password 1234 5 1 1 Network This section is intended for network configuration In order to...

Page 10: ...n Web Server Default password is 1234 Retype password Repeat the password for confirmation when changing it 5 1 3 Statistics This section provides the information regarding the established TCP connect...

Page 11: ...Default value is 0 0 0 0 Trap destination3 IP address of the 3rd trap message destination Default value is 0 0 0 0 SNMP Simple Network Management Protocol OFF SNMP enabled Default parameter ON SNMP di...

Page 12: ...re of up to 8 different areas in real time in ELAN Configuration Web Server s section Monitoring see 5 1 8 Monitoring and receive a trap message to up to 3 trap destination IP addresses see 5 1 4 SNMP...

Page 13: ...uipped with 2 open collector outputs C1 and C2 designed for electricalal appliance connection Nor mally outputs can be used to open close garage doors activate lights heating watering and much more Wh...

Page 14: ...ported parameters OIDs actions available for each parameter which can be configured via SNMP as well as value range and an example comment Please note that the tables reflect the parameters described...

Page 15: ...estored Input2 state OFF name 1 3 6 1 4 1 34093 1 2 62 2 0 get set text e g Input 2 is restored Input3 state OFF name 1 3 6 1 4 1 34093 1 2 62 3 0 get set text e g Input 3 is restored Input4 state OFF...

Page 16: ...C1 control 1 3 6 1 4 1 34093 1 2 200 1 0 get set 0 1 0 turn OFF output 1 turn ON output Output C2 control 1 3 6 1 4 1 34093 1 2 200 2 0 get set 0 1 0 turn OFF output 1 turn ON output 5 2 7 Monitoring...

Page 17: ...ase contact your local distributor More up to date information about your device and other products can be found at the manufacturer s website www eldes lt 6 2 Restoring Default Parameters 1 Power dow...

Page 18: ...MadeintheEuropeanUnion www eldes lt...

Reviews: