9-6
HOW TO USE YOUR MOTORHOME’S
EQUIPMENT
WATER HEATER OPERATION
Gas operation
(i)
Ensure that the water heater has been
filled with water and that the outside flue
cover has been removed.
(ii)
Using the Ultrastore control knob, turn
the dial to the desired temperature setting
then turn the outer ring to the flame
position.
(iii)
Once the Ultrastore is switched on a
green light is visible within the switch and
the unit will now try and ignite.
(iv)
If within approximately 10 seconds, the
Ultrastore fails to ignite then a red failure
light will also appear. If this happens wait
30 seconds before trying again.
230V Operation
Simply depress the Electrical switch fitted next to
the gas control to the 230V position. This will
turn on the water heaters electrical element. It is
imperative that there is water in the heater
whenever the Gas or Electric is switched on.
SPACE HEATER OPERATION
Gas Operation
(i)
Turn the gas
control on
top of the
heater to the
desired
setting and
depress the
knob.
(ii)
Keeping the
control knob depressed look into the
viewing window and see if the gas ignites.
If you have an automatic ignitor then you
should hear it ticking and eventually see
the pilot light. If however you have Piezo
ignition then you will have to manually
depress the ignitor repeatedly until you
see the pilot light.
(iii)
Once the pilot light is lit keep the control
knob depressed for a further 20 seconds
to allow the thermocouple to operate.
(iv)
If the heater fails to ignite please wait 20
seconds for trying again.
Electric Operation
(i)
Simply depress the main switch on the
Ultraheat control panel to the 230V
position.
(ii)
Then set the power rating you require on
the panel at either 500w, 1000w or
2000w.
FAN OPERATION (Option)
The blown air function of the space heater is
controlled by the three-position switch on top of
the heater.
(i)
Position 0 is
off.
(ii)
Position A
operates the
fan in
automatic
mode. In this
position the
fan will only
run when there is sufficient heat to
require the air to be circulated.
(iii)
The third Position will operate the fan at
all times.
(iv)
The speed of the fan is controlled by the
Gas control
Ultrastore control
Ultraheat control
Fan control
Summary of Contents for AutoQuest
Page 5: ...1 2 INTRODUCTION ...
Page 11: ...4 2 MOTORWAY HANDLING ...
Page 13: ...5 2 ARRIVING ON SITE ...
Page 21: ...7 2 GAS SAFETY ADVICE ...
Page 35: ...9 12 HOWTO USEYOUR MOTORHOME S EQUIPMENT 1 2 4 3 5 6 ...
Page 36: ...9 13 HOWTO USEYOUR MOTORHOME S EQUIPMENT 7 8 10 9 11 12 ...
Page 53: ...11 4 CARE OFYOUR MOTORHOME ...
Page 55: ...12 2 STORAGE ...
Page 61: ...15 2 MOTORHOME CONSTRUCTION ...
Page 63: ...16 2 EQUIPMENT LIST ...
Page 64: ...17 1 ELECTRICAL DRAWINGS ELECTRICAL DRAWINGS AUTOQUEST ...
Page 65: ...17 2 ELECTRICAL DRAWINGS ...
Page 69: ...18 4 TECHNICAL SPECIFICATIONS ...
Page 75: ...20 4 GLOSSARY ...
Page 79: ...21 4 SERVICE DOCUMENTS ...