6-10
GETTING STARTED
Troubleshooting
(a) If the pump will not run:
•
Check at least one tap is open
•
Turn the pump isolation switch off and on again
•
Check the battery condition
•
Check the mains isolator switch is on
•
Check the pump isolator switch is on
•
Check the contacts in the plug and socket are clean and making contact
•
Check wiring connections
•
Check fuse (see fuse box)
(b) If the pump cylces on/off with all taps and shower closed:
•
Check for air or water leaks in taps and piping
•
Check that non return valve in socket is free from grit by pushing a suitable blunt object,
for example a ballpoint pen into the socket nipple against the non-return valve holding
the valve open to dislodge trapped grit.
•
Recalibrate the system (see calibration section of the installation section)
(c) If pump motor runs steadily and does not stop after 30-40 seconds:
•
Check all connections in pipework
•
Recalibrate the system
Diagnostic Codes
To aid with troubleshooting the LED on the back of the Watermaster IC has a number of different
flash codes as described in the table below:
LED
State
Description
Green
Constant On
Tap open, pump running
Green
Fast Flash (< 1 sec)
In Calibration Mode
Green
200ms blink every 5 sec
Calibrated and ready for use
Green
200ms blink every 10 sec
Un-calibrated
Green
200ms blink every 15 sec
Suspended due to dry run need to turn pump switch on
and off
Green
200ms blink every 20 sec
Suspended due to low battery voltage, turn pump switch
on/off, need to charge battery
Winterising
Watermaster IC does not require any additional winterising. For details of how to drain your
water system for winterising please see www.whalepumps.com/rv.
Summary of Contents for 2016 Buccaneer
Page 5: ...CONTENTS 4 CONTENTS ...
Page 7: ...1 2 INTRODUCTION ...
Page 11: ...2 4 GENERAL SAFETY ...
Page 17: ...3 6 PREPARING FOR THE ROAD ...
Page 50: ...7 3 ELECTRICAL SYSTEM MAINS UNIT MAINS UNIT MAINS UNIT MAINS UNIT MAINS UNIT ...
Page 51: ...7 4 ELECTRICAL SYSTEM ...
Page 111: ...11 2 STORAGE ...
Page 115: ...12 4 WARRANTY ...
Page 117: ...13 2 CARAVAN CONSTRUCTION ...
Page 119: ...14 2 EQUIPMENT LIST ...
Page 120: ...15 1 ELECTRICAL DRAWINGS WIRING DIAGRAM BUCCANEER ...
Page 121: ...15 2 ELECTRICAL DRAWINGS ROAD LIGHTS BUCCANEER ...
Page 129: ...17 6 GLOSSARY ...
Page 137: ...19 2 CHANGE OF OWNERSHIP ...
Page 139: ...20 2 CHANGE OF ADDRESS ...
Page 141: ...21 2 USEFUL ADDRESSES ...
Page 145: ...22 4 INDEX Designed and Printed by Preset Graphics Ltd Tel 01332 549278 MY2016 Ref 21434 ...