background image

A maximum of eight switching codes can be pro-

grammed. Teaching is carried out using the in-

ternal programming button 

Q/S

 (refer to page 2 

„Programming switching transmitter“).

SWITCH-OFF Function

When  the  switch-off  function  is  enabled,  the 

RCL07 can be switched off using the switch but

-

ton.

When  switched  off,  separately  programmed 

transmitters must be used to trigger a call, the so-

called „Priority transmitters“.

These transmitters trigger calls even if the RCL07 

is switched off. 
Priority transmitters must be programmed sepa

-

rately  in  the  RCL07  and  can  be  deleted  in  the 

same  way  as  call  transmitters  (refer  to  page  3 

„Programming priority transmitter“). 

RCL07 switch OFF: 

Press the button     

(>10 seconds) until the green LED goes off. 

RCL07 switch ON: 

Press the button   (approx. 

5 seconds) until the green LED lights up.

After a voltage interruption, the RCL07 is always 

switched on. 
Jumper J1 can be used to 

disable

 or 

enable

 the 

switch-off function. This function is disabled in the 

factory settings (J1 in pos. 1), to change refer to 

page 2 „Changing the switch-off function“.

Please note that it is not possible to con-

trol the power supply when the switch-off  

function is activated.

BATTERY UNDERVOLTAGE

If the capacity of the battery of a call tranmitter or 

a priority transmitter is low, the transmitter sends 

an  undervoltage  telegram.  The  relay  channel  2 

(CH2) is switched for approx. one second and the 

LED 

 signals the undervoltage by flashing.

 

If the RCL07 receives an undervoltage telegram 

when the acknowledgment function is activated, 

the undervoltage is only displayed on the device 

after acknowledgment of the call.

Now  replace  the  battery  of  the  call  transmitter. 

When the RCL07 receives two consecutive tele-

grams from this transmitter without an undervolt-

age  message,  the  receiver  automatically  resets  

the undervoltage indication.

Operating Modes (OM)

The  operating  mode  is  selected  by  repeatedly 

pressing the programming button 

R

 in the pro-

gram step „Programming the call transmitter“ (re-

fer to page 2). 

PULSE    

1-button operation

If a transmitter button A/B/C/D is pressed, the cor

-

responding relay is triggered for one second. 

ON/OFF    

2-button operation

The relay can selectively be switched ON or OFF. 

The  transmitter  button  A  or  C  switch  ON,  the 

transmitter button B or D switch OFF.

Caution!

 In order to change the operating mode, 

first delete the transmitter transmission code and  

then subsequently programming an other trans

-

Model

1

2

3

4

J2

J1

Q/

S

R

Technical Details

Frequency: 

868.30 MHz/916.50 MHz 

Modulation:  

FSK

Coding:  

Easywave

 

EasywavePlus

Power supply: 

12-24 V DC

Current consumption: 
 

12 V DC: 

19 mA stand by

 

 

65 mA load *)

 

24 V DC: 

11 mA stand by

 

 

31 mA load *)

Max. contact rating: 

30 V / 1 A / 30 W

Output: 

2 potential-free  

 

relay contacts 

 

 

(1 CO and 1 NO)

Operating temperature: -20 °C to +60 °C

Degree of protection:   IP54

Dimensions (w/l/h):  

35/80/20 mm

Weight: 

38.0 g

Connecting cable: 

Ø 5 mm

*)  

Both relays are switched.

Scope of Delivery

Call receiver RCL07, operating instruction

Intended Use

The unit may only be operated with safety extra 

low voltage (SELV) and may only be used as a ra

-

dio control for switching devices with safety extra 

low voltage (SELV).
The manufacturer shall not be liable for any dam

-

age caused by improper or non-intended use

.

RCL07  Call Receiver with internal programming

GB

Ca

ble entry 

with cord  

grip

Switch button 

Care function activate/deactivate 

green LED

illumi

nates:  RCL07 ready for

 

 operation

flashes:  

Care function active

not light:   RCL07 is off (Priority

 

channels are still  

 

 

being received)

or

RCL07 without power supply

Acknowledge button Quit

Call acknowledge

red LED

illuminat

es:  Call received

flashes:  

Battery low voltage

Safety Advice

 Before using the device, carefully read 

through the operating instructions!

Caution!

 Observe the permissible supply volt

-

age and the max. contact rating!

Have faulty radio controls checked by the 

manufacturer!

Do  not  make  any  unauthorized  alterations  or 

modifications to the receiver!

Function

The call receiver RCL07 has two channels. Chan-

nel 1 (CH1) is used for signal incoming calls. If 

the  RCL07  receives  an  undervoltage  telegram, 

the channel 2 (CH2) switches for one second.

 

The  following  applications  can  be  realized  with 

this:

CALL Function

When the RCL07 receives the telegram from a 

call transmitter, channel 1 (CH1) switches accord

-

ing to the operating mode selected.

A maximum of 32 transmission codes for call and 

priority senders can be programmed. 

Teaching is carried out using the programming 

button 

R

 (refer to page 2 „Programming call trans-

mitter“).
When the care function is activated

 

and

 

a call has 

been received, the red LED 

R

 continuously illu

-

minates.

 

This call can be acknowledged using the taught 

acknowledge transmitter or the button 

Quit

 (refer 

to „Acknowledge function“). 

ACKNOWLEDGE Function

A maximum of eight transmission codes can be 

programmed. 
Teaching is carried out using the internal pro-

gramming button 

Q/S

 (refer to page 2 „Program-

ming acknowledge transmitter“).
The acknowledge function can be activated or 

deactivated by setting jumper J2 accordingly. The 

acknowledgment function is activated at the fac-

tory.

Activated 

(jumper J2 in position 4) 

When the acknowledge function is activated, LED 

R

 will light up 

red

 once a call is incoming. 

This call can be acknowledged using an acknowl-

edgement transmitter, or on the RCL07 using the 

Quit

 button. LED 

R

 will stop illuminating and out-

put channel 1 (CH1) will be reset. 

Deactivated 

(jumper J2 in position 3 and 4) 

If the acknowledge function is deactivated, an in

-

coming call can not be acknowledged and LED 

Quit

 will not light up. The device will switch to 

output channel 1 (CH1) in accordance with the 

operating mode selected.

CARE Function

Using  the  care  function,  the  call  function  is 

 

disabled for 15 minutes. 

Disabling the call function is carried out by a sep

-

arate switching transmitter using the transmitter 

button 

B

 or 

D

Alternatively,  the  call  function  can  also  be  disa

-

bled  by  pressing  the  button   

 

(

>

  1.6  s  but      

<

10 s) on the RCL07.   

The call function is automatically reactivated after 

15 minutes or can be reactivated using the trans-

mitter button 

A

 or 

C

, or on the receiver using the 

button   . 

RCL07E5002B02    

868.30 MHz

RCL07E6002B02    

916.50 MHz

Programming button Q/S

Teach and delete the acknowledge 
and switch transmitter  

Programming  

button R

Teaching and 
delete the  
call transmitter 