13. MAINTENANCE
Maintenance work on the installation must be carried out by suitably qualified
personnel using special materials and tools.
The purpose of maintenance is to check the installation to ensure that it
complies with current regulations. Maintenance of the system is divided into
two points:
The panel
The rest of the system
13.1 The
panel
The panel must be checked at least once a year as follows:
Contact rails and conduit connections.
Joints and connections must be visually inspected. The panel must also be
cleaned of dust, moisture, etc. during the inspection.
Components
Maintenance and inspections must be carried out in accordance with the
manufacturer’s instructions for each component. All components must be
tested to ensure that they function mechanically as intended.
External casings and covers
The panel’s outer casings must be checked visually. Covers must be
inspected to ensure that they provide the correct protection against direct
touch.
All covers must be checked for faults on closing devices.