background image

BRIEF INSTRUCTIONS

BRIEF INSTRUCTIONS

Via Naviglio Alto,24/A 43100 PARMA (ITALY) - Tel. 0521.772021 / Fax 0521.270218

e-mail: [email protected]

www.elcos.it

PRESS TO START

THE ENGINE

WHEN THE

CONTROL UNIT

IS IN MANUAL

OPERATION

STOPPING DUE TO:

INSUFFICIENT OIL

PRESSURE

USER IS

CONNECTED TO

GENERATOR

LA TENSIONE

RETE È PRESENTE

USER IS CONNEC-

TED TO MAINS

STOPPING DUE TO:

• BELT BREAKAGE

• BATTERY

CHARGING

FAILURE

KEY ENABLED WHEN

THE CONTROL PANEL

IS IN MANUAL OPERA-

TION.

, WHEN

THE ENGINE IS

RUNNING

PRESS TO DIVERT

THE POWER USERS TO

THE MAINS OR TO THE

GENERATOR

®

TECHNICAL DATA

- BATTERY POWER

SUPPLY

12 VDC or 24 VDC

- DEGREE OF PROTECTION

• FRONT

IP40

• REAR

IP00

- DIMENSIONS (LxHxP) mm

600 x 485 x 235

INSTRUMENTS

MAINS VOLTMETER

GENERATOR VOLTMETER

GENERATOR FREQUENCY METER

MAINS/GENERATOR AMMETER

TOTAL HOUR METER

PARTIAL HOUR METER

BATTERY VOLTMETER

FUEL LEVEL INDICATOR

SYNCHRONOUS READING

OF THREE INSTRUMENTS

PUSH BRIEFLY

TO SHOW THE

INSTRUMENTS,

HOLD DOWN TO

VERIFY THE LED

TEST OR THE

GENERAL ALARM

SILENCING

AND TO VIEW

THE HISTORICAL

RECORD

ENGINE IS

RUNNING

OFF

AUT

MAN

TEST

G

THE ENGINE

COOLING

IS DISPLAYED

THE DISPLAY SHOWS

CLOCK FOR

PROGRAMMING THE

STARTING OR THE

STOPPING

OF THE GENSET

THE FUEL LEVEL

INDICATOR

IS DISPLAYED

PARTIAL

HOUR METER.

SHOWS HOURS OF

OPERATION SINCE

THE LAST TIME

THE GENERATOR

SET WAS

SWITCHED ON.

TOTAL HOUR METER

PRESS TO

SELECT THE

FUNCTIONS OF:

• AUT

• OFF

• MAN

• TEST

REMOTE CONTROLS
DESCRIPTION INDICA-

TION
ON THE
DISPLAY

STARTING

STOPPING

EJP STARTING

EJP

CONSENT

SWITCHING

START

STOP

START EJP

EJP

CALL FROM EX-

TERNAL VOLT-

METRIC RELAY

THE GLOW PLUGS

PREHEATING

IS DISPLAYED

DISPLAY SHOWS:

THE TOTAL OPERA-

TING HOURS

AND THE GENSET

FREQUENCY

THE DISPLAY SHOWS:

• VOLTMETER

.

MAINS/GENSET

AMMETER

MAINS

• GENSET

FRE-

QUENCY

METER

GENERA-

TOR

BATTERY

EMERGENCY

STOP

OFF

AUT

MAN

TEST

AVAILABLE

FAULT

STARTING

FAILURE

ALARM

STOPPING DUE TO

OVERFREQUENCY

STOPPING DUE

TO ENGINE

OVERHEATING

ALARM DUE TO

NO FUEL

THE GENERATOR

VOLTAGE IS ON:

LED ON

• GENERATOR

UNDER-VOLTAGE:

FLASHING LED

(A FLASH THEN A

PAUSE)

• GENERATOR

OVER-VOLTAGE:

FLASHING LED

(TWO FLASHES

THEN A PAUSE)

CUMULATIVE

ALARM

PRESS TO RESET

THIS OPERATION

REACTIVATES

ALL THE BLOCKED

FUNCTIONS

.

MAINS VOLTAGE

IS PRESENT

LA TENSIONE

RETE È PRESENTE

BATTERY CHARGER

IN OPERATION

PRESS TO STOP

THE ENGINE WHEN

THE CONTROL

UNIT IS IN

MANUAL

OPERATION

G

%

%

START

STOP

VOLT

AMP

HZ

h

!

A1

OFF

MAN

AUT

TEST

h

MAN

STOP

START

G

RESET