Installation / mounting of LT2SMKU-T 

 
The 

LT2MSKU-T

 can be used as wall-mounting or desktop unit. 

 
Do not install the device in the neighbourhood of strong electromagnetic fields (i.e. close to 
loudspeakers, TV-sets or the like), since radiation sources and interferences of such kind can 
reduce the transmission range. Further, the place of installation should be protected from 
direct sun radiation, heat sources and humidity and should also be dust-free, if possible. 
 
If the 

LT2MSKU-T

 is used as desktop device, it should be placed on a plain and dry table 

surface.  
 
For mounting the device to the wall, use the existing casing pockets (key holes) to fix the 
unit with help of the 3 

×

 35 screws and 6 mm dowels tension-free to a plain and dry wall 

surface. Before inserting the dowels, make sure that there are no concealed supply lines in 
the wall. 
 
After connection of the signal cables, the device is ready for work. 
 
To 

put the sub-unit

 

LT2MSKU-T into operation,

 the supply voltage has to be applied. 

This is indicated by the green LED turning ON. The applied supply voltage and successful 
initialization promptly start activation of the transmission line if a repeater ZWR or an 
NT2MS has been connected. This will take a few seconds and is indicated by the flashing of 
LED DSL1 (in two-pair mode also DSL2). Upon initial start-up, the system ramps up in 
structured operating mode (default state). 

Note: The disconnecting switch must be in 

position „Operation“!

 If the default state does not comply with the desired configuration, 

the LT2MSKU-T and the NT2MS have to be reconfigured with help of the management 
system. The configuration data are stored in the LT resp. NT as non-volatile information. 
 

 

1

 

Short description

/ continued 

 
The ISDN primary multiplex access uses the CRC-4 method as per ITU-T G.704 and G.706. 
This ensures additional protection against faulty synchronization and allows to check the 
transmission quality between the S2M interface (E1, G703) and the digital local exchange. 

 

With the unstructured 2 Mbps fixed connection (D2MU, unstructured operating mode 
(transparent mode)) the line terminating unit / network terminating unit 

LT2MSKU-T

 

transmits the complete 2 Mbps signal, irrespective of the bit sequence, in both directions, i.e. 
there is no frame synchronization against the 2 Mbps signal and no CRC4 application. The 
received digital signals at the V2M interface (E1) are only checked with regard to existence, 
HDB3 code error and AIS (Alarm Indication Signal). 

 

A controlled loop (via Sa6 bits or SHDSL overhead) to be established close to the S2M 
interface (E1) of the NT2MS permits in all modes of operation a distinct fault localization, 
i.e. to recognize whether the failure belongs to the area of responsibility of the network 
operator or, respectively, the subscriber. The 

LT2MSKU-T

 allows a loop close to the UKS 

port(s). The activation (initiation) of the loop(s) is carried out with help of the MSP (Modu-
lar Service PC) with ENMS (ELCON Network Management Software) via the PC interface. 

 

The various settings of the SHDSL can be configured with a PC per SHDSL overhead (EOC 
channel) from the 

LT2MSKU-T

. Local configuration of the SHDSL is possible via the PC / 

RS232/V.24 interface. This requires a PC with respective ENMS software. Optionally, the 
system can be configured as well by the DIL switches which are arranged on the circuit 
board of the 

LT2MSKU -T

. This means, configuration is executed for each system indi-

vidually. 

 

Note: 

Once the system has been configured via the EOC channel, the settings of the 
DIL switches will have no effect! 

 

For powering a regenerative repeater, an optionally available remote power supply module 
(

FSP2M

) can be used, which can be integrated into the 

LT2MSKU-T

. For this, the device 

has to be opened (

 Mounting of remote power supply module). 

 

Further, the 

LT2MSKU-T

 can be switched between the operating modes „one pair“ and 

„two-pair“. The respective switch can be found inside the device on the motherboard, so the 
device has to be opened for switching. Besides, the 

LT2MSKU-T

 can be operated not only 

in one-system mode, but also in double-system mode, whereby in the latter case the 

LT2MSKU-T 

card contains two fully separate systems, to which two 

NT2MSKU

 can be 

connected via a twin-wire copper cable. 

22 

3

Summary of Contents for LT2MSKU-T

Page 1: ...ELCON Systemtechnik GmbH 2008 LT2MSKU T Digital Transmission System for 2 Mbps signals via copper cable Operating instructions Art no 101388 1...

Page 2: ...and installation of the components of the SHDSL transmission system atten tion shall be paid to the safety precautions as stipulated by IEC 61340 5 1 Safety precautions during thunderstorms Keep away...

Page 3: ...nge 32 V 75 V Current consumption 1 A Power consumption without with FSP2M 7 W 30 W Fuse protection F700 1 6 A T 250 V IEC 60127 3 IV Remote power supply module 112 V 3 V 59 mA nominal values Contents...

Page 4: ...he operating state of the NT2 subscriber terminal equipment TE This allows the network operator to run its transmis sion network as self sustaining system independent from the connected subscriber ter...

Page 5: ...the unstructured 2 Mbps fixed connection D2MU unstructured operating mode transparent mode the line terminating unit network terminating unit LT2MSKU T transmits the complete 2 Mbps signal irrespecti...

Page 6: ...ing the device can be installed with the display elements on top whereby the interfaces point down The clamp feet will be attached in turned position Device housing LED display Film with legends Upper...

Page 7: ...it in inclined position and then place it onto the housing bottom part Figre 18 Closing the housing 2 Interfaces All interfaces are situated on the rear side of the LT2MSKU T UB power supply T3an FPE...

Page 8: ...th a line digit rate of 7731 3 kbaud one pair system or 3891 3 kbaud two pair system is used Transmission is effected on each path in duplex mode bidirectionally The echo cancella tion technique is ap...

Page 9: ...of overvoltage protection components at the input and output a transceiver and a framer From physical point of view the interface is an RJ 45 jack A switch on the rear side allows to put the device in...

Page 10: ...upply a tripolar power pack should be used If in case of local power supply the LT2MSKU T is powered by a power pack other than the specified one e g older 2 pole types without FPE earthing conductor...

Page 11: ...KU T The required configuration program is provided on the enclosed floppy disc that contains further information in the files Readme txt and Licence txt The PC interface represents an EIA RS232C inte...

Page 12: ...crewdriver symbol and slightly tilt it outwards 2 4 The housing springs open at one side 5 Again turn the device the upside is now showing to the top 6 Unlocking as described under 3 Figure 13 Unlocki...

Page 13: ...n FSP enabled ON OFF OFF OFF ON OFF OFF OFF OFF OFF ON Error in the remote power supply circuit operation with FSP ON OFF OFF OFF OFF OFF OFF OFF OFF OFF 1 Hz Urgent alarm at V2Man LOS LOF BER ON OFF...

Page 14: ...guration switches will have no effect Another switch on the rear side of the device LT2MSKU T serves for switching between normal mode of operation and test mode In position Operation the V2M interfac...

Reviews: