Maintenance
Filter Change
Drier filter keeps recovered refrigerant clean and moisture free. Filter must be replaced
periodically in order to ensure the unit is working properly. Using expired filters voids
warranty. EKM 1500 filters need to be replaced every 100 kg of operation. After 80 kgs of
operation, the unit will start reminding the user at every start up. When the filter reaches
100 kg, the unit will be locked.
1.
Order a new filter.
2.
Replace the filter.
3.
Turn on the unit.
4.
Press ESC for 5 seconds.
5.
Select FILTER CHANGE and press ENTER.
6.
Use UP & DOWN buttons to write password then press ENTER.
Vacuum Pump Oil Change
In order to maintain pump efficiency, vacuum pump oil must be changed regularly.
Contaminated oil might lead to irreversible damage to mechanical components of the
vacuum pump. Change vacuum pump oil under the following conditions:
Summary of Contents for EKM 1500