ART. 09/07800-00
PAGINA 3 DI 4
1
7
6
4
3
2
5
1. LCD Display: 3 ½ digits, character 15mm high
2. Light Button Switch> Press this button to swtch on back light if the dark
circumstance light makes the reading difficulty when measuring, the
light will be automatically turned off in 5 seconds. Press again to switch
it on again. If the battery is in weak power, the light will be dimmed.
3. Rotary Switch: use this switch to select functions and ranges
4. VΩmA Input Jack
5. COM Input Jack
6. Ω10A Input Jack
7. Data-hold Switch (HOLD)
3. Safety Information
3-1 The meters are designed according to IEC-61010 concerning electronic
measuring instruments with an over-voltage category (CAT III) and
pollution 2.
3-2 Follow all safety and operating instructions to ensure that the meter is
used safely and is kept in good operating condition.
3-3 Safety symbols:
Important safety information, refer to the operating manual.
Dangerous voltage may be presence.
Double insulation (protection Class II)
4. Special Cautions for Operation
4-1 The meters can be safe only according to standard procedures when
used in conjunctions with the supplied test leads. To replace damaged
test leads with only the same model or same electric specifications.
4-2 To avoid risk of electric shock, do not use the meters before the cover
is in place.
4-3 The range switch should be right position for the testing.
4-4 To avoid electric shock and damaging the instruments, the input
signals are forbidden to exceed the specified limits.
4-5 When measuring TV set or switched power, attention should be paid
to the possible pulses that may bring destruction to the circuit.
4-6 Range switch position is forbidden to be changed at random during
measurement.
4-7 Take caution against shock in the course of measuring voltage higher
than DC 60V & AC 30V.
4-8 Protection fuse should be replaced only with same type and same
specification.
5. GENERAL SPECIFICATIONS
5-1 Max Voltage between input terminal and Earth Ground: CAT III 600V
5-2 Over-range Indication: display “1” for the significant digit.
5-3 Automatic display of negative polarity “-” .
5-4 Low Battery Indication: ‘ ’ displayed
5-5 Max LCD display: 1999 (3 ½ digits)
5-6 Fuse protection:
F-250mA/600V (Ø5x20mm)
5-7 Power Supply:
9V battery, 6F22 or NEDA 1604
5-8 Operating temperature:
0°C to 40°C (relative humidity <85%)
1. Overview
The multimeter is characterized at slim size, portable, stable performance
and anti-dropping capacity. Using 3 ½ digits LCD monitor with character
15mm high, they offer clear readings. With overall circuitry design centering
on large-scale IC A/D converters in conjunction and over-load protection
circuit, the meters give excellent performance and exquisite making as a
handy utility instrument.
The meters can be used to measure AC & DC voltage, DC current,
resistance, positive diode voltage fall and continuity.
2. Panel Layout
DIGITAL MULTIMETER ART. 09/07800-00 NI2100
OPERATION MANUAL
5-9 Storage temperature:
-10°C to 50°C ((relative humidity <85%)
5-10 Guaranteed precision temperature: 23±5°C (relative humidity <85%)
5-11 Dimensions:
69x138x31mm (with holster)
5-12 Weight:
approx 170gr. (including battery)
6. Testing Specifications
Accuracy is specified for a period of year after calibration and at 18°C to
28°C (64°F to 82°F) with relative humidity to 75%.
6-1 DC Voltage
Range
Resolution
Accuracy
200mV
0,1mV
±(0.5% of rdg ± 3 digits )
2V
1mV
±(0,5% of rdg ± 3 digits)
20V
10mV
±(0,5% of rdg ± 3 digits)
200V
100mV
±(0,5% of rdg ± 3 digits)
600V
1V
±(0,8% of rdg ± 3 digits)
Range
Resolution
Accuracy
20µA
0,01µA
±(1,0% of rdg ± 3 digits)
200µA
0,1µA
±(1,0% of rdg ± 3 digits)
2mA
1µA
±(1,0% of rdg ± 3 digits)
20mA
10µA
±(1,0% of rdg ± 5 digits)
200mA
100µA
±(1,5% of rdg ± 5 digits)
10A
10mA
±(3,0% of rdg ± 10 digits)
Range
Resolution
Accuracy
200Ω
0,1Ω
±(0,8% of rdg ± 5 digits)
2KΩ
1Ω
±(0,8% of rdg ± 2 digits)
20KΩ
10Ω
±(0,8% of rdg ± 2 digits)
200KΩ
100Ω
±(0,8% of rdg ± 2 digits)
2MΩ
1KΩ
±(1,0% of rdg ± 5 digits)
Range
Resolution
Accuracy
200V
100mV
±(1,2% of rdg ± 10 digits)
600V
1V
±(1,2% of rdg ± 10 digits)
- Input Impendence:
1MΩ
- Overload protection:
600V for 200mV range,
effective DC or AC 600V for other ranges
- Frequency Range: 40 to 400Hz
- Response: average, calibrated in rms of sine wave
- over-load protection: 600V effective value
- over-load protection: 600V effective value
6-4 Resistenza
6-3 DC Current
6-2 AC Voltage
Range
Resolution
Function
1mV
Display: read approximate forward
voltage of diode
Range
Function
Built-in buzzer will sound if resistance is lower
than 50Ω
6-5 Diode Test
6-6 Continuity
- over-load Protection: 600V effective value
- forward DC current: approximate 1mA
- Reversed DC voltage: approximate 3.0V
- over-load protection:
600V effective value
- open circuit voltage:
approximate 3.0V