background image

 

focus HAND 3 main unit: 

 
Connections: 
The main unit has 2 DMX connections and a fixed mains lead. The mains input voltage can range from 
90Vac to 240Vac. The DMX connections on the back are for DMX input and output on 5 pin XLR. 
 
DMX connection : 
 
Pin 

Description 

Ground/Screen 

Data - 

Data + 

loop thru to other XLR5 pin 4 

loop thru to other XLR5 pin 5 

 
For best results the antenna has to be oriented as far away as possible from metal parts, including the 
housing. 
 
LED indications: 
 
The LED’s on the front indicate Power On, Active and Receive 
 
LED 

Meaning 

On 

Power is on and the internal processor is working 

Active 

DMX control is taken over from the lighting desk 

Receive  A valid signal is received from the remote 
 

Operation: 

 
Activation (with HTP merge): 
Type in the code [+] [+] [ENTER] 
This action activates the receiver unit, taking over the DMX control. The DMX output will be an Highest 
take Precedence merge of the DMX input and the channels generated by the remote. 
 
Activation (without HTP merge): 
Type in the code [+] [+] [0] [ENTER] 
This action activates the receiver unit, taking over the DMX control. Merge function is disabled, the 
DMX output is only generated by the remote. 
 
Deactivation: 
Type in the code [-] [-] [ENTER] 
This action deactivates the receiver unit switching back the DMX control to the lighting desk. 
 
Single dimmer at full: 
Type in [1..512] [ENTER] 
 ex: 
 [1] [ENTER] 
 
Single dimmer at percentage: 
Type in [1..512] [@] [0..9] 
The level will be set in 10% steps 
ex: 
[2] [@] [5] 
 

 dimmer 2 at 50% 

 
Adjusting the level: 
Type in: [@] [4] 
 

 selected dimmers at 40% 

 

Summary of Contents for focus HAND 3

Page 1: ...focus HAND 3 512 channel wireless DMX riggers remote Users Manual Software version 1 0 ...

Page 2: ...s them into the proper DMX values The receiver unit has to be connected between the lighting consoles DMX output and the dimmers DMX input where it will take over the control of the DMX line This can be activated with the remote unit so the receiver can be permanently connected Not only one spot at a time can be controlled but also groups and level can be adjusted from off to 100 Even groups and m...

Page 3: ...m replace it with a fresh one and close the lid with the same M3x4mm screws Be sure not to throw the old battery in the normal dustbin but remove it adequately Using alkaline batteries is recommended Keypad layout Key illumination The keys on the transmitter are illuminated While a key is pressed the unit is transmitting indicated by bright illumination of the keys When releasing the key the illum...

Page 4: ...he lighting desk Receive A valid signal is received from the remote Operation Activation with HTP merge Type in the code ENTER This action activates the receiver unit taking over the DMX control The DMX output will be an Highest take Precedence merge of the DMX input and the channels generated by the remote Activation without HTP merge Type in the code 0 ENTER This action activates the receiver un...

Page 5: ... ENTER removes dimmer 3 from selection 3 THRU 8 removes dimmers 3 to 8 Clear Stage remove all To clear the selection press 0 ENTER Stepping thru dimmers Press FUNC then you can use NEXT PREV UP and DOWN for stepping thru the dimmer channels and adjusting the total level When finished press ENTER Toggle between presets Press ENTER for switching between the current and previous setting Using groups ...

Page 6: ...coding this may only be done by qualified personnel because you ll need to open the cabinet Unplug the main power supply Open the cabinet 6 screws Find the location of the settings it is a jumper array marked by 0 at the front Set the jumper to the correct setting Close the cabinet Changing the remote s encoding this can be done at any time even to use 1 remote for up to 3 locations Switch off the...

Page 7: ...mpliance with FCC regulation shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio television reception CAUTION Changes or modifications not expressly approved by ELC lighting and Leprecon LLC may void the users authority to operate this equipment R TTE regulations 433 92MHz EU version The HF modules...

Page 8: ......