4
focus HAND 3 main unit:
Connections:
The main unit has 2 DMX connections and a fixed mains lead. The mains input voltage can range from
90Vac to 240Vac. The DMX connections on the back are for DMX input and output on 5 pin XLR.
DMX connection :
Pin
Description
1
Ground/Screen
2
Data -
3
Data +
4
loop thru to other XLR5 pin 4
5
loop thru to other XLR5 pin 5
For best results the antenna has to be oriented as far away as possible from metal parts, including the
housing.
LED indications:
The LED’s on the front indicate Power On, Active and Receive
LED
Meaning
On
Power is on and the internal processor is working
Active
DMX control is taken over from the lighting desk
Receive A valid signal is received from the remote
Operation:
Activation (with HTP merge):
Type in the code [+] [+] [ENTER]
This action activates the receiver unit, taking over the DMX control. The DMX output will be an Highest
take Precedence merge of the DMX input and the channels generated by the remote.
Activation (without HTP merge):
Type in the code [+] [+] [0] [ENTER]
This action activates the receiver unit, taking over the DMX control. Merge function is disabled, the
DMX output is only generated by the remote.
Deactivation:
Type in the code [-] [-] [ENTER]
This action deactivates the receiver unit switching back the DMX control to the lighting desk.
Single dimmer at full:
Type in [1..512] [ENTER]
ex:
[1] [ENTER]
Single dimmer at percentage:
Type in [1..512] [@] [0..9]
The level will be set in 10% steps
ex:
[2] [@] [5]
dimmer 2 at 50%
Adjusting the level:
Type in: [@] [4]
selected dimmers at 40%