background image

 

Group of dimmers: 
It’s possible to select multiple dimmers at one time. This can be a range, using [THRU], or separate 
dimmers using [+] and [-]. 
ex: 
[1] [THRU] [6] [ENTER] 

 dimmer 1 to 6 selected 

[3] [+] [6]  [+] [1] [0] [ENTER] 

 dimmer 3,6,10 selected 

[1] [THRU] [6] [+] [1] [0] [ENTER] 

 dimmer 1 to 6 and 10 selected 

[1] [THRU] [6] [–] [5] [ENTER] 

 dimmer 1 to 4 and 6 selected 

 
Adding dimmers: 
To add dimmers to a selection use the [+]. 
ex: 
[+] [4] [ENTER] 

 adds dimmer 4 to previously selected dimmers 

[+] [6] [THRU] [10] 

 adds dimmers 6 to 10 

 
Removing dimmers: 
Using [-] removes dimmers from the selection. 
ex: 
[–] [3] [ENTER] 

 removes dimmer 3 from selection 

[–] [3] [THRU] [8] 

 removes dimmers 3 to 8 

 
Clear Stage (remove all): 
To clear the selection press: 
[0] [ENTER] 
 
Stepping thru dimmers: 
Press [FUNC], then you can use [NEXT], [PREV], [UP] and [DOWN] for stepping thru the dimmer 
channels and adjusting the total level. When finished press [ENTER]. 
 
Toggle between presets: 
Press [ENTER] for switching between the current and previous setting. 
 
Using groups 
 
The focus hand can store up to 50 selection groups. 
 
Recording a group 
 
First select any number of channels in the normal way. 
 
Next press: 
[Func] [- / Store] [ 

 / group] number of the group [Enter] 

 
Recalling a Group 
 
To recall a group press for example: 
[

 / Group] [1] [Enter]   

 

 Group 1 at Full 

[

 / Group] [2] [+] [1]  [

] [6] [@] [5] 

 Group 2 and channels 1 thru 6 at 50% 

 

Summary of Contents for focus HAND 3

Page 1: ...focus HAND 3 512 channel wireless DMX riggers remote Users Manual Software version 1 0 ...

Page 2: ...s them into the proper DMX values The receiver unit has to be connected between the lighting consoles DMX output and the dimmers DMX input where it will take over the control of the DMX line This can be activated with the remote unit so the receiver can be permanently connected Not only one spot at a time can be controlled but also groups and level can be adjusted from off to 100 Even groups and m...

Page 3: ...m replace it with a fresh one and close the lid with the same M3x4mm screws Be sure not to throw the old battery in the normal dustbin but remove it adequately Using alkaline batteries is recommended Keypad layout Key illumination The keys on the transmitter are illuminated While a key is pressed the unit is transmitting indicated by bright illumination of the keys When releasing the key the illum...

Page 4: ...he lighting desk Receive A valid signal is received from the remote Operation Activation with HTP merge Type in the code ENTER This action activates the receiver unit taking over the DMX control The DMX output will be an Highest take Precedence merge of the DMX input and the channels generated by the remote Activation without HTP merge Type in the code 0 ENTER This action activates the receiver un...

Page 5: ... ENTER removes dimmer 3 from selection 3 THRU 8 removes dimmers 3 to 8 Clear Stage remove all To clear the selection press 0 ENTER Stepping thru dimmers Press FUNC then you can use NEXT PREV UP and DOWN for stepping thru the dimmer channels and adjusting the total level When finished press ENTER Toggle between presets Press ENTER for switching between the current and previous setting Using groups ...

Page 6: ...coding this may only be done by qualified personnel because you ll need to open the cabinet Unplug the main power supply Open the cabinet 6 screws Find the location of the settings it is a jumper array marked by 0 at the front Set the jumper to the correct setting Close the cabinet Changing the remote s encoding this can be done at any time even to use 1 remote for up to 3 locations Switch off the...

Page 7: ...mpliance with FCC regulation shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio television reception CAUTION Changes or modifications not expressly approved by ELC lighting and Leprecon LLC may void the users authority to operate this equipment R TTE regulations 433 92MHz EU version The HF modules...

Page 8: ......

Reviews: