In select mode: 

E/-

   

Select different item 

Press Encoder

 

Go to Edit mode 

In Edit mode: 

E/-

   

Change the value of the item 

Press Encoder

 

Go to Select mode 

 

DMX port as output 

 
When a port is set up as a DMX output it can operate in the following modes; 

 

Disabled 

à

 the DMX output is disabled 

 

Outzero 

à

 the DMX sends out a DMX test signal with all channels at 0% 

 

Single  

à

 the output sends out the DMX values of the selected (primary) 

Art-Net, sACN or Shownet universe. The DMX output is enabled the first time 
it detects the DMX universe on the network (or internal DMX inputs). If the 
universe on the network fails, the DMX output will go into DMX hold. 

 

HTP   

à

 like single, but merges up to three DMX universes (primary, 

secondary and tertiary) in highest takes precedence. 

 

Priority 

à

 Will output the Universe assigned to the primary if primary is 

not present or available the universe assigned to secondary will be output 

 

FlexPatch 

à

 Can output a complex merge of three universes with a 

different merge or patch per channel. This can be set up in the dmXLAN 
software 

 
DMX port as input 

 
When a port is set up as a DMX input it can operate in the following modes; 

 

Disabled 

à

 the DMX input does nothing 

 

Normal 

à

 any valid DMX is sent onto the network (and internal use) 

using the selected universe (Art-Net) 

 

Backup 

à

 the DMX input will not send data if the selected universe is 

present on the network. If the selected universe is not present on the network 
for several seconds and the input has valid DMX, then it will send DMX data. 
If another sender starts sending the same universe, the input will go back into 
backup mode. 

 

Summary of Contents for dmXLAN node3

Page 1: ...dmXLAN node3 User Manual ...

Page 2: ...__________________________________________________________________________________ ELC dmXLAN node3 User Manual ...

Page 3: ...s mount Power over Ethernet DLN3TPOE_FI truss mount Power over Ethernet fully isolated DLN3S surface mount DLN3S_FI surface mount fully isolated DLN3W recessed wall mount DLN3W_FI recessed wall mount fully isolated DLN3DIN DIN version DLN3DIN_FI DIN version fully isolated 3 Bi directional DMX ports on the rear panel XLR RDM compatible Supports sACN Art Net Shownet 2 Ethernet ports Neutrik Ethercon...

Page 4: ...ounted onto a wall The Surface Mount unit has 3 bi directional DMX ports located on the front of the device The DMX ports can be ordered in male or female version any combination is possible as well as a version with fully isolated DMX ports DLN3T_FI There is also one Ethernet connection Neutrik Ethercon on the front of the node3 SM Another internal Ethernet connection RJ45 is located on the back ...

Page 5: ...Description 1 Ground screen 2 Data 3 Data 4 5 All DMX ports are bi directional can act as input or output with RDM preparation and can optionally be supplied in a fully isolated FI version The ports also have internal 120 Ohm terminator resistors and line biasing for RDM This product may only be used for controlling dimmers and moving lights Using the product outside of these specifications will r...

Page 6: ...rom the ELC website at www elclighting com The front panel control options will be explained below Main display Encoder Change the view on the display to see the device ID IP address status software version etc Press Encoder Enter the setup menu Setup menu Encoder Select one of the setup items Exit Setup DMX port 1 DMX port 2 DMX port 3 Set ID Network Options Press Encoder Activate the selected op...

Page 7: ...d HTP à like single but merges up to three DMX universes primary secondary and tertiary in highest takes precedence Priority à Will output the Universe assigned to the primary if primary is not present or available the universe assigned to secondary will be output FlexPatch à Can output a complex merge of three universes with a different merge or patch per channel This can be set up in the dmXLAN ...

Page 8: ... that the ID is not used Network options Use the Select and Edit modes to change the values of the IP address and the netmask For normal Art Net operation the netmask should be set to 255 0 0 0 and the IP address should be between 2 0 0 1 and 2 254 254 254 node3 Truss Mount Power 100 240 VAC 47 440 Hz 10VA max Dimensions 200 x 160 x 45 mm Weight 1 2 kg node3 Surface Mount Power Power over Ethernet...

Page 9: ...pparatus including amplifiers that produce heat Unplug this apparatus during lightning storms or when unused for long periods of time Do not place the unit on unstable surfaces Do not place any objects on the power cord Protect it from being walked on or pinched particularly at the plugs and the point where they exit from the device If the power cord or the mains plug is damaged let a qualified te...

Page 10: ...ilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitut...

Page 11: ...Which refer to this declaration are manufactured in the Netherlands and complies with the following product specifications and harmonized standards Safety LVD Low Voltage Directive 2014 35 EU EN62368 1 EMC 2014 30 EG EN55032 ROHS II 2011 65 EU With the presumption that the equipment is used and connected according to the manual supplied with the equipment All signal input and output connections mu...

Reviews: