Wiring diagram 

Infeed, relay outputs and digital inputs 

 

Maximum switching capacity per relay: 

 5A 250V~ ; 2A 30V= 

  Maximum switching capacity over all relays: 10A 
  This value may not be exceeded. 

 Do not connect any different voltages to the relay: 

With 250V~ circuit: Only connect the phase conductor: Do not connect phase and neutral conductors at the relay con-
tact. With low-voltage circuit (DC): Only connect the plus pole. 

Analogue inputs 

 

SMSB482

1

2

3

4

5

6

7

8

-

-

+

DIGITAL INPUTS

12÷24V

1000mA

NC COM NO

NC COM NO

NC COM NO

NC COM NO

RELAY 1

RELAY 2

RELAY 3

RELAY 4

S

W

1

S

W

2

S

W

3

S

W

4

S

W

5

S

W

6

S

W

7

S

W

8

LOAD1

LOAD2

LOAD3

LOAD4

For each relay, the output maximum current is 5A.

Total sum must not exceed 10A at 250V~

AN1 AN2

B/RX

A/TX

ANALOG 

INPUTS

RS

RS

232/

485

85÷265V~

12÷24V

1000mA

-

+

N

E

A

R

T

H

L

SAMPLE ELECTRICAL CONNECTION

 

DRY

WET

SMSB482

SMSB482

0..10V +24V

GND

S1

S2

AN AN

1/

2

probe

ANALOG INPUTS

 

transmitter

0..10V

LOOP

S1

S2

AN AN

1/

2

ANALOG INPUTS

 

transmitter

0..20mA

LOOP

-

+

ON

1

2

3

4

5

probe

AN AN

1/

2

ANALOG INPUTS

PT1000

ON

1

2

3

4

5

AN2

AN1

ON

1

2

3

4

5

ON

1

2

3

4

5

ON

1

2

3

4

5

AN AN

1/

2

ANALOG INPUTS

PT100

ON

1

2

3

4

5

probe

probe

Summary of Contents for SMSB242

Page 1: ...User s manual SMSB242 SMSB482 SMS Switch Butler...

Page 2: ...2...

Page 3: ...ply new functionality or new instructions for products already sold The manufac turer cannot be held liable for loss or damage direct or indirect which may result from use of the product The product i...

Page 4: ...roni cally and physically including photocopies or saving are only permitted to the user for personal use and prohibited in all other cases without special written authorization The use copying modifi...

Page 5: ...solar radiation No devices which radiate heat No objects which generate a strong electromagnetic field No corrosive liquids or chemical substances The SMSB242 SMSB482 was designed for operation at tem...

Page 6: ...6 Use the same voltage level for all relays With high voltage circuits only the phase conductor may be connected via the re lay contacts...

Page 7: ...gue inputs common earth 9 Code switch for analogue inputs 30 4 59 mm 61 70 mm 45 40 mm 35 42 mm Mo TuWeThFrSaSu IN8 IN4 GSM GPRS IN1 IN2 IN3 IN5 IN6 IN7 RE1 RE2 RE3 RE4 AN1 AN2 SMSB482 I O 2 1 7 6 8 5...

Page 8: ...NPUTS 12 24V 1000mA NC COM NO NC COM NO NC COM NO NC COM NO RELAY 1 RELAY 2 RELAY 3 RELAY 4 SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 LOAD1 LOAD2 LOAD3 LOAD4 For each relay the output maximum current is 5A Tota...

Page 9: ...osed contacts The device is password protected and can store and manage up to eight users In order to simplify installation and operation of the device the SMSB242 SMSB482 is equipped with a large int...

Page 10: ...The installation software of the SMSB242 SMSB482 is stored in the Micro SD mass storage In order to start the butler in MSD mode and install the software you must proceed as follows 1 Switch off the...

Page 11: ...Date time The system date can be updated in this screen the system date is synchronized with the operating system Windows Date and time are only used for the datalogger function Switch The relays are...

Page 12: ...l damages caused including negligence arising out of or in connection with the use or the inability to use the product The user has been advised by Elbro of the possibility of such damages Neither Elb...

Page 13: ...ter a four digit password to be able to send SMS commands The default password is made up of four zeroes 0000 Please refer to the SMS commands section to get an overview of all available commands Enab...

Page 14: ...rs who can work in case of failure It allows sending sequentially the digital input alarming messages observing the order found on the list of users with a time in terval default 5 minutes that can be...

Page 15: ...correctly set the dip switch considering the chosen sensor Type of sensor Selection of the type of the sensor probe for example PT100 or PT1000 Conversion table In this table all desired values can b...

Page 16: ...h a customizable text message On this mask the message text for each relay can be individually configured Response message The relay can only be controlled by SMS commands If you send a command to swi...

Page 17: ...tivating at the same time the system it is connected to This function can be set through the following modes Exchange simple relay exchange is done ON OFF Pulse a programmable pulse of 1 up to 65535 s...

Page 18: ...form this function the device is equipped with two super capacitors they require at least 30 minutes charging before any SMS can be sent The charge status can be viewed as a percentage in the System S...

Page 19: ...a list of SMS commands with their relevant description and example Command Description Example PW R 1 4 0 deactivates relay outputs from 1 to 4 0000 R1 0 PW R 1 4 1 activates relay outputs from 1 to...

Page 20: ...istive 2A 30V DC Maximum total load applicable to the device 10A Inputs SMSB242 4 p free contact digital inputs SMSB482 8 potential free contact digital inputs 2 analogue inputs 0 10V 0 20mA PT100 PT1...

Reviews: