27
INSTALLATION
6
The cookers afford class ‘1’ protection against overheating of surrounding surfaces.
The installation conditions, concerning protection against overheating of the surfaces
adjacent to the cooker, must conform to fig. 6.1 and 6.2.
The appliance must be kept no less than 300 mm away from any side wall which exceeds
the height of the hob surface (fig. 6.1).
The appliance must be housed in heat resistant units.
The synthetic veneer materials and the glue used must be resistant to a temperature of
150°C in order to avoid ungluing or deformations.
Curtains must not be fitted immediatly behind appliance or within 500 mm of the sides.
If the cooker is located on a pedestal it is necessary to provide safety measures to prevent
falling out.
The appliance must be housed in heat resistant units.
The walls of the units must not be higher than work top and must be capable of
resisting temperatures of 75 °C above room temperature.
Do not instal the appliance near inflammable materials (eg. curtains).
■
Gas connection made using
rubber hose which must be visible
and easily inspected or using rigid
or flexible metal pipe.
A space of at least 2 cm must be
left between the cooker and any
adjacent furniture, which must not
exceed the height of the cooktop.
450 mm
650 mm
300 mm
20 mm
20 mm
500 mm
Fig. 6.1
50 cm
50 cm
Fig. 6.2