LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation, maintenance and conversion of the appliance
must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
TABLE FOR THE CHOICE OF THE INJECTORS
Cat: II 2H 3+
G30/G31
28-30/37 mbar
G20
20 mbar
Cat: II 2E 3+
G30/G31
28-30/37 mbar
G20/G25
20/25 mbar
BURNERS
Nominal
Power
[kW]
Reduced
Power
[kW]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Semi-rapid (SR)
1,75
0,45
66
101
Rapid (R)
3,00
0,75
87
129
Triple-ring (TR)
3,80
1,50
98
141
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Semi-rapid (SR)
3,50
Rapid (R)
6,00
Triple-ring (TR)
7,60
Some models - for the gas category check the data label attached on the appliance
GB