Fig. 10.12
G
Flame correct
Flame faulty in
primary air
Flame with excess
primary air
Flame Flame
Flame
faulty in
correct
with excess
primary air
primary air
long, yellow
clear
short and sharp
and
interior blue
too blue interior
trembling
cone
cone tending to
detach
CAUSE
air regulating
correct
air regulating
tube, too
distance of
tube, too
closed
the tube
open
ADJUSTMENT OF THE OVEN AND
GRILL BURNERS MINIMUM
This needs to be done only for the oven
burner (the grill is a fixed capacity) by
acting on the thermostat in the following
way:
– turn on the burner by setting the ther-
mostat knob on position 10
– remove the knob and unscrew the by-
pass screw (fig. 10.12) about three
times by passing a small flat screw-
driver (Ø 3 mm blade, 100 mm length)
through the panel opening
– re-mount the knob and let the oven
heat up for about 10 minutes, then
bring the knob to position 1 (minimum)
to operate the thermostat by-pass
– after having removed the knob again
and being very careful not to turn the
tap rod, slowly screw the by-pass
screws “G” (fig. 10.12) until you obtain
a flame of 3-4 mm in height.
N.B. For G30/G31 the by-pass screw
must be fixed thoroughly.
IMPORTANT
All intervention regarding installa-
tion maintenance and conversion
of the appliance must be fulfilled
with original factory parts.
The manufacturer declines any lia-
bility resulting from the non-com-
pliance of this obligation.
LUBRICATION OF THE GAS TAPS
The operations must be executed by a
qualified technician.