background image

w w w . e l a t i o n l i g h t i n g . c o m 

SIXPAR  300IP

 / SIXPAR 300WMG

 User  Manual  ver 

S A F E T Y   I N S T R U C T I O N S 

The 

SIXPAR  300IP

 / SIXPAR 300WMG

 

is  an  extremely  sophisticated  piece 

of  electronic equipment.  To  guarantee  a  smooth  operation,  it  is  important 

to  follow  the guidelines  in  this  manual.  The  manufacturer  of  this  device  will 

not  accept responsibility  for  damages  resulting  from  the  misuse  of  this  fixture 

due  to  the disregard  of the information  printed  in this manual. 

This  device  falls  under 

PROTECTION  CLASS  1

.  It’s  essential  this  device  be 

grounded  properly.  Only  qualified  personnel  should  perform  all  electrical 
connections. 

 A 

 U 

 T 

 I        O 

 N 

 S

 

UNPLUG POWER BEFORE SERVICING FIXTURE

 

NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT 

NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE

 

SENSITIVE PERSONS MAY SUFFER AN EPILETIC SHOCK 

RISK  GROUP  3  -  RISK  OF  EXPOSURE  TO  ULTRAVIOLET  UV  RADIATION! 
FIXTURE  EMITS  HIGH  INTENSITY  WAVELENGTH  OF  ULTRAVIOLET  UV  LIGHT 
FROM  THE  UV  LED.  WEAR  PROPER  EYE  AND  SKIN  PROTECTION.  AVOID 
PROLONGED PERIODS O F  E X P O S U R E  T O  U V  L E D . AVOID W E A R I N G  
WHITE  COLOR  CLOTHING  AND/OR  USING  UV  PAINTS  ON  SKIN.  AVOID 
DIRECT  EYE  AND/OR  SKIN  EXPOSURE  AT  DISTANCES  LESS  THAN  11  FEET 
(3.3m).  DO  NOT  OPERATE  FIXTURE  WITH  DAMAGED/MISSING  EXTERNAL 
COVERS.  DO  NOT  LOOK  DIRECTLY  INTO  THE  UV  LIGHT  AND/OR  VIEW  UV 

LIGHT DIRECTLY  WITH  OPTICAL INSTRUMENTS  THAT MAY  CONCENTRATE THE LIGHT/RADIATION  OUTPUT. 
INDIVIDUALS SUFFERING FROM  A RANGE OF  EYE CONDITIONS,  SUNLIGHT EXPOSURE DIS-ORDERS,  OR 
INDIVIDUALS  USING  PHOTOSENSITIVE  MEDICATION,  MAY  RECEIVE  DISCOMFORT  IF  EXPOSED  TO  THE 
ULTRAVIOLET UV LIGHT EMITTED FROM THE UV LED. 

For  proper  operation,  follow  the 

Installation 

guidelines  described  in  this  manual.  Only  qualified

and  certified  personnel  should  perform  installation  of  this  fixture  and  only  the  original  rigging
parts  (brackets)  included  with  this  fixture  should  be  used  for  installation.  Any  modifications  will
void the original  manufactures  warranty  and increase  the risk of damage  and/or  personal  injury.

Never  look  directly  into  the  light  source  of  this  fixture  to  prevent  risk  of  injury  to  your  retina,
which may  induce  blindness.  Those  suffering  from 

E P I L E P S Y 

should  avoid  looking  directly  into

the  light source  of this unit at all times.

Always disconnect from main power source before performing any type of service and/or cleaning
procedure. Only  handle  the  power  cord  by  the  plug  end,  never  pull  out  the  plug  by tugging
the wire portion  of the cord.

Do  not  operate  this  fixture  if  the  power  cord  has  become  frayed,  crimped  and/or  damaged.
If the power  cord is damaged,  replace  it immediately  with a new one of similar  power  rating.

Summary of Contents for SIXPAR 300IP

Page 1: ...ELATION SIXPAR 300IP SIXPAR 300WMG user manual SIXPAR 300IP SIXPAR 300WMG user manual...

Page 2: ...any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information cont...

Page 3: ...O N T E N T S General Information 4 Warranty 7 Safety Instructions 8 General Guidelines 9 Fixture Overview 10 Fixture Installation 11 Understanding DMX 13 Fixture Menu 16 DMX Channel Functions And Val...

Page 4: ...f protection against particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one wh...

Page 5: ...X Output Cable 3 3 ft 1m Manual Warranty Card WARRANTY REGISTRATION Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must b...

Page 6: ...com sales elationlighting com ELATION PROFESSIONAL B V Junostraat 2 6468 EW Kerkrade The Netherlands 31 45 546 85 66 Fax 31 45 546 85 96 www elationlighting eu info elationlighting eu ELATION PROFESS...

Page 7: ...er by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this wa...

Page 8: ...ERATE FIXTURE WITH DAMAGED MISSING EXTERNAL COVERS DO NOT LOOK DIRECTLY INTO THE UV LIGHT AND OR VIEW UV LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT RADIATION OUTPUT INDIVID...

Page 9: ...flammable materials from the surface 1 6 feet 0 5m DO NOT attempt installation and or operation without knowledge how to do so DO NOT allow operation by persons who are not qualified to operate this t...

Page 10: ...e l a t i o n l i g h t i n g c o m SIXPAR 300IP SIXPAR 300WMG User Manual ver F I X T U R E O V E R V I E W 1 MODE Button 2 UP Button 3 DOWN Button 4 ENTER Button 5 Power IN 6 DMX IN 7 DMX Out 8 Powe...

Page 11: ...s temperature Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 210 lbs 95 kg Fixture installation must alw...

Page 12: ...hers calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the ins...

Page 13: ...o ensure proper DMX data transmission always use the SIXPAR series IP rated DMX cables listed in the OPTIONAL ACCESSORIES section at the end of this manual When using several DMX fixtures try to use t...

Page 14: ...and out data connections never split or Y your DMX connections DMX 512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs The use of a terminator...

Page 15: ...channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of contro...

Page 16: ...igate through the different function menus Once you reach a desired menu press the ENTER button to select that menu The variable field that can be adjusted within the selected menu will begin to flash...

Page 17: ...pecifications are subject to change without any prior written notice MENU OPTIONS VALUES DESCRIPTION CHANNEL CH 06 07 08 12 DMX Channel Mode DMX MODE ADDR 001 512 DMX Address Setting SLAVE MODE SALVE...

Page 18: ...Manual ver w w w e l a t i o n l i g h t i n g c o m DIMMING CURVES The DimCurve menu allows you to select one of the following preset dimming curves Standard Stage TV Architec or Theatre See diagram...

Page 19: ...NNEL VALUE FUNCTION 6 CH 7 CH 8 CH 12 CH 1 1 1 1 RED 0 255 Red 0 100 2 2 2 2 GREEN 0 255 Green 0 100 3 3 3 3 BLUE 0 255 Blue 0 100 4 4 4 4 WHITE 0 255 White 0 100 5 5 5 5 AMBER 0 255 Amber 0 100 6 6 6...

Page 20: ...32 35 RED BLUE 36 39 RED WHITE 40 43 RED AMBER 44 47 RED UV 48 51 GREEN BLUE 52 55 GREEN WHITE 56 59 GREEN AMBER 60 63 GREEN UV 64 67 BLUE WHITE 68 71 BLUE AMBER 72 75 BLUE UV 76 79 WHITE AMBER 80 83...

Page 21: ...BLUE WHITE AMBER 196 199 RED BLUE WHITE UV 200 203 RED BLUE AMBER UV 204 207 RED WHITE AMBER UV 208 211 GREEN BLUE WHITE AMBER 212 215 GREEN BLUE WHITE UV 216 219 GREEN BLUE AMBER UV 220 223 GREEN WH...

Page 22: ...to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A...

Page 23: ...ing 0 100 5 Variable Dimming Curve Modes CONTROL CONNECTIONS 4 DMX Channel Modes 6 7 8 12 4 Button Touch Control Panel LCD Menu Display IP DMX and Power In Out SIZE WEIGHT Length 14 4 365mm Width 6 2...

Page 24: ...Manual ver w w w e l a t i o n l i g h t i n g c o m PHOTOMETRIC DATA DIMENSIONAL DRAWINGS Please Note Specifications and improvements in the design of this unit and this manual are subject to change...

Page 25: ...8 ft 3m IP Data Link Cable SIXPAR 3MPLC 9 8 ft 3m IP Power Link Cable SIXPAR 5MDLC SPECIAL ORDER ITEM 16 4 ft 5m IP Data Link Cable SIXPAR 5MPLC SPECIAL ORDER ITEM 16 4 ft 5m IP Power Link Cable SIXP...

Page 26: ......

Reviews: