DMX Channel  Values / Functions  (12 DMX Channels) 

Specifications  are subject  to change  without  any prior written  notice. 

MODE / CHANNEL

 

VALUE

 

FUNCTION

 

6 CH

 

7 CH

 

8 CH

 

12 CH

 

COLOR MACROS (continued) 

152-155

BLUE + WHITE + AMBER 

156-159

BLUE + WHITE + UV 

160-163

BLUE + AMBER + UV 

164-167

WHITE + AMBER + UV 

168-171

RED + GREEN + BLUE + WHITE 

172-175

RED + GREEN + BLUE + AMBER 

176-179

RED + GREEN + BLUE + UV 

180-183

RED + GREEN +WHITE + AMBER 

184-187

RED + GREEN + WHITE + UV 

188-191

RED + GREEN + AMBER + UV 

192-195

RED + BLUE + WHITE + AMBER 

196-199

RED + BLUE + WHITE + UV 

200-203

RED + BLUE + AMBER + UV 

204-207

RED + WHITE + AMBER + UV 

208-211

GREEN + BLUE + WHITE + AMBER 

212-215

GREEN + BLUE + WHITE + UV 

216-219

GREEN + BLUE + AMBER + UV 

220-223

GREEN + WHITE + AMBER + UV 

224-227

BLUE + WHITE + AMBER + UV 

228-231

RED + GREEN + BLUE + WHITE + AMBER 

232-235

RED + GREEN + BLUE + WHITE + UV 

236-239

RED + GREEN + BLUE + AMBER + UV 

240-243

RED + GREEN + WHITE + AMBER + UV 

244-247

RED + BLUE + WHITE + AMBER + UV 

248-251

GREEN +BLUE + WHITE + AMBER + UV 

252-255

RED + GREEN + BLUE + WHITE + AMBER + UV 

10 

COLOR CHASE MACROS 

00-20

NO Function 

21-40

30 Color Chase 

41-60

6 Color Chase 

61-80

Color Fade Chase 

81-255

NO Function 

11 

COLOR CHASE MACROS SPEED 

00-255

Chase Speed of CHANNEL 10 - SLOW to FAST 

12 

DIMMING MODES 

0-20

STANDARD 

21-40

STAGE 

41-60

TV 

61-80

ARCHITECTURAL 

81-100

THEATER 

101-255

NO Function 

Summary of Contents for SIXPAR 300IP

Page 1: ...ELATION SIXPAR 300IP SIXPAR 300WMG user manual SIXPAR 300IP SIXPAR 300WMG user manual...

Page 2: ...any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information cont...

Page 3: ...O N T E N T S General Information 4 Warranty 7 Safety Instructions 8 General Guidelines 9 Fixture Overview 10 Fixture Installation 11 Understanding DMX 13 Fixture Menu 16 DMX Channel Functions And Val...

Page 4: ...f protection against particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one wh...

Page 5: ...X Output Cable 3 3 ft 1m Manual Warranty Card WARRANTY REGISTRATION Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must b...

Page 6: ...com sales elationlighting com ELATION PROFESSIONAL B V Junostraat 2 6468 EW Kerkrade The Netherlands 31 45 546 85 66 Fax 31 45 546 85 96 www elationlighting eu info elationlighting eu ELATION PROFESS...

Page 7: ...er by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this wa...

Page 8: ...ERATE FIXTURE WITH DAMAGED MISSING EXTERNAL COVERS DO NOT LOOK DIRECTLY INTO THE UV LIGHT AND OR VIEW UV LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT RADIATION OUTPUT INDIVID...

Page 9: ...flammable materials from the surface 1 6 feet 0 5m DO NOT attempt installation and or operation without knowledge how to do so DO NOT allow operation by persons who are not qualified to operate this t...

Page 10: ...e l a t i o n l i g h t i n g c o m SIXPAR 300IP SIXPAR 300WMG User Manual ver F I X T U R E O V E R V I E W 1 MODE Button 2 UP Button 3 DOWN Button 4 ENTER Button 5 Power IN 6 DMX IN 7 DMX Out 8 Powe...

Page 11: ...s temperature Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 210 lbs 95 kg Fixture installation must alw...

Page 12: ...hers calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the ins...

Page 13: ...o ensure proper DMX data transmission always use the SIXPAR series IP rated DMX cables listed in the OPTIONAL ACCESSORIES section at the end of this manual When using several DMX fixtures try to use t...

Page 14: ...and out data connections never split or Y your DMX connections DMX 512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs The use of a terminator...

Page 15: ...channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of contro...

Page 16: ...igate through the different function menus Once you reach a desired menu press the ENTER button to select that menu The variable field that can be adjusted within the selected menu will begin to flash...

Page 17: ...pecifications are subject to change without any prior written notice MENU OPTIONS VALUES DESCRIPTION CHANNEL CH 06 07 08 12 DMX Channel Mode DMX MODE ADDR 001 512 DMX Address Setting SLAVE MODE SALVE...

Page 18: ...Manual ver w w w e l a t i o n l i g h t i n g c o m DIMMING CURVES The DimCurve menu allows you to select one of the following preset dimming curves Standard Stage TV Architec or Theatre See diagram...

Page 19: ...NNEL VALUE FUNCTION 6 CH 7 CH 8 CH 12 CH 1 1 1 1 RED 0 255 Red 0 100 2 2 2 2 GREEN 0 255 Green 0 100 3 3 3 3 BLUE 0 255 Blue 0 100 4 4 4 4 WHITE 0 255 White 0 100 5 5 5 5 AMBER 0 255 Amber 0 100 6 6 6...

Page 20: ...32 35 RED BLUE 36 39 RED WHITE 40 43 RED AMBER 44 47 RED UV 48 51 GREEN BLUE 52 55 GREEN WHITE 56 59 GREEN AMBER 60 63 GREEN UV 64 67 BLUE WHITE 68 71 BLUE AMBER 72 75 BLUE UV 76 79 WHITE AMBER 80 83...

Page 21: ...BLUE WHITE AMBER 196 199 RED BLUE WHITE UV 200 203 RED BLUE AMBER UV 204 207 RED WHITE AMBER UV 208 211 GREEN BLUE WHITE AMBER 212 215 GREEN BLUE WHITE UV 216 219 GREEN BLUE AMBER UV 220 223 GREEN WH...

Page 22: ...to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A...

Page 23: ...ing 0 100 5 Variable Dimming Curve Modes CONTROL CONNECTIONS 4 DMX Channel Modes 6 7 8 12 4 Button Touch Control Panel LCD Menu Display IP DMX and Power In Out SIZE WEIGHT Length 14 4 365mm Width 6 2...

Page 24: ...Manual ver w w w e l a t i o n l i g h t i n g c o m PHOTOMETRIC DATA DIMENSIONAL DRAWINGS Please Note Specifications and improvements in the design of this unit and this manual are subject to change...

Page 25: ...8 ft 3m IP Data Link Cable SIXPAR 3MPLC 9 8 ft 3m IP Power Link Cable SIXPAR 5MDLC SPECIAL ORDER ITEM 16 4 ft 5m IP Data Link Cable SIXPAR 5MPLC SPECIAL ORDER ITEM 16 4 ft 5m IP Power Link Cable SIXP...

Page 26: ......

Reviews: