E R R O R CO D E S
When power is applied, the unit will automatically enter a “
Reset/Test
” mode. This mode brings all the
internal motors to a home position. If there is an internal problem with one or more of the motors an
error code will flash in the display in the form of “
XXer
” were as
XX
will represent a function number.
For example, when the display shows “
0Er
” it means there is some type of error with the Pan motor. If
there are multiple errors during the start-up process they will all flash in the display. For example: if the
fixtures has errors on
Channel 1
,
2
, and
5
all at the same time, you will see the error message “
01Er
”,
“
02Er
”, and “
05Er
” flash repeated 5 times.
If an error does occur during the initial start-up procedure the fixture will self-generate a second reset
signal and try to realign all the motors and correct the errors. If the error persists after a second
attempt a third attempt will be made. If after a third attempt all the errors have not been corrected
the fixture will make the following determinations:
• 3 or More Errors
: The fixture cannot function properly with three or more errors therefore the
fixture will place itself in a stand-by mode until subsequent repairs can be made.
• Less Than 3 Errors
: The fixture has less than 3 errors; therefore, most other functions will work
properly. The fixture will attempt to operate normally until the errors can be correct by a technician.
The errors in question will remain flashing in the display as a reminder of internal errors.
Error Codes subject to change without notice
ERROR CODES
DESCRIPTION
PAN Er
TILT Er
Movement is not located in the default position after the reset. This
message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed, or magnet is missing) or there is a motor
failure (defective motor or a defective motor IC drive on the main PCB).
This error may also be displayed if the head/yoke was blocked during TILT
Er a reset function.
Cyan Color Er
Magenta Color Er
Yellow Color Er
CTO Color Er
Color Wheel Er
Focus Er
Zoom Er
Iris Er
Animation Er
Animation Rot Er
Movement is not located in the default position after the reset. This
message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed, or magnet is missing) or there is a motor
failure (defective motor or a defective motor IC drive on the main PCB).