Power Spot 700™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page
11
10.
Internal Cooling Fan –
This fixture is equipped with two high-velocity variable
speed fans mounted in the base to aid in the cooling process. These fans are
designed to vary their velocity at different operating temperatures. When the
fixture reaches a predetermined internal operating temperature the fans function
at high speeds. The higher speeds provide better cooling associated with higher
operating temperatures during long use. When the fixture is operating at a lower
temperature the fans operate at low speed. Be sure to keep all vents clean,
blocked cooling vents can shorten lamp life and reduce the fixtures reliability. For
more information on the fan functions see page 23, section 3.9.7.
11.
Electronics Fuse Holder –
This housing holds a 250v/2A GMA fuse (120v
operation). Never defeat this fuse, this fuse is designed to protect the electronics
in the event of severer power fluctuations. In the event of fuse failure, always be
sure to replace this fuse with an exact match unless otherwise instructed by an
authorized Elation technician.
12.
Powercon Connector –
This power jack is designed to be used only with the
Neutrik Powercon adapter included with your fixture. This jack provides main
power to your fixture.
13.
Power Switch –
The switch is used to control main power to fixture’s electronics.
14.
Lamp Fuse Holder –
This housing holds a 250v/10A GMA fuse (120v operation).
Never defeat this fuse, this fuse is designed to protect the lamp in the event of
severer power fluctuations. In the event of fuse failure, always be sure to replace
this fuse with an exact match unless otherwise instructed by an authorized Elation
technician.
15.
Mode Select Button –
This button is used to access the fixture’s main system
menu and on-board programming functions.
16.
Enter Select Button –
This button is used to select and confirm a menu function
when working in the fixture’s operating system.