background image

 
 

w w w . e l a t i o n l i g h t i n g . c o m  

 

                                                                                           

27

                                                PLATINUM SEVEN™ User Manual

 

ELATION© PLATINUM SEVEN™ 

DMX Channel Values / Functions Version 1 - (40 DMX Channels) 

Supports Software Versions: 

 1.1.3 

Features are subject to change without any prior written notice. 

*Rotation direction (Clockwise or Counterclockwise) of effects depends on orientation of the fixture head and Pan/Tilt settings.

 

MODE / CHANNEL 

VALUE 

FUNCTION 

BASIC 

STAND 

EXTEND 

14 

21 

28 

  

COLOR PRESETS DIMMER 

0-255 

Dimmer 0 to 100% 

15 

22 

29 

  

SHUTTER, STROBE 

0-31 

Shutter CLOSED 

32-63 

Shutter OPEN (LEDs ON) 

64-95 

Strobe Effect SLOW to FAST 

96-127 

Shutter OPEN (LEDs ON) 

128-159 

Pulse Effect In Sequences 

160-191 

Shutter OPEN (LEDs ON) 

192-223 

Random Strobe Effect SLOW to FAST 

224-255 

Shutter OPEN (LEDs ON) 

16 

23 

30 

  

DIMMER INTENSITY 

0-255 

Dimmer 0 to 100% 

  

  

31 

  

DIMMER INTENSITY FINE 

0-255 

Dimmer FINE Adjustment 

17 

24 

32 

  

DIMMER MODES 

0-20 

Standard 

21-40 

Stage 

41-60 

TV 

61-80 

Architectural 

81-100 

Theatre 

101-255 

Default to Setting on Fixture 

18 

25 

33 

  

MOTORIZED ZOOM 

0-255 

ZOOM Adjustment from SMALL to BIG 

  

  

34 

  

MOTORIZED ZOOM FINE 

0-255 

ZOOM FINE Adjustment 

19 

26 

35 

  

CHASE PATTERNS 

0-14 

NO FUNCTION (LEDs OFF) 

15-30 

Chase 1 

31-46 

Chase 2 

47-62 

Chase 3 

63-78 

Chase 4 

79-94 

Chase 5 

95-110 

Chase 6 

111-126 

Chase 7 

127-142 

Chase 8 

143-158 

Chase 9 

159-174 

Chase 10 

175-190 

Chase 11 

191-206 

Chase 12 

207-222 

Chase 13 

223-238 

Chase 14 

239-255 

Chase 15 

 

Summary of Contents for PLATINUM SEVEN

Page 1: ...PLATINUM SEVEN user manual E L A TI ON PLATINUM SEVEN user manual...

Page 2: ...ries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient an...

Page 3: ...O N T E N T S General Information 4 Warranty 6 Safety Instructions and Guidelines 7 Overview 9 Installation 10 System Menu 14 DMX Channel Functions And Values 24 LED Groups 29 Error Codes 30 Cleaning...

Page 4: ...nance UNPACKING Every fixture has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If th...

Page 5: ...chase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the ret...

Page 6: ...r by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this war...

Page 7: ...of this fixture and only the original rigging parts omega brackets included with this fixture should be used for installation Any modifications to the fixture and or the mounting hardware included wil...

Page 8: ...wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always install fixture with an appropriately rated safety...

Page 9: ...rray 2 Control Panel 3 LCD Menu Function Display 4 MODE ESC Button 5 LEFT Button 6 DOWN Button 7 ENTER Button 8 RIGHT Button 9 UP Button 10 Carrying Handle s 11 RJ45 Ethernet Input 12 RJ45 Ethernet Ou...

Page 10: ...rotection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture is 14 to 1...

Page 11: ...he included Omega Brackets using a M10 screw fitted through the center hole of the Omega Bracket The fixture provides a built in rigging point for a Safety Cable on the mounting bracket assembly as il...

Page 12: ...y inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully o...

Page 13: ...ION OF OTHER LIGHTING FIXTURES WILL VARY ART NET CONNECTION When connecting fixture to a network switch to control multiple devices a Gigabit Ethernet Switch that supports IGMP Internet Group Manageme...

Page 14: ...u can navigate through the different functions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adjusting press the ENTER button to activate that f...

Page 15: ...DMX ON OFF Address Via DMX No DMX Status Hold Close Shutter Auto Program Auto Run If No DMX Pan Reverse ON OFF Pan Reverse Movement Tilt Reverse ON OFF Tilt Reverse Movement Pan Degree 630 540 Pan De...

Page 16: ...ode DMX Channel Modes Basic Mode Extended Mode User Mode A User Defined Channel Assignment User Mode B User Mode C Edit User Mode Edit User Mode A Max Channel XX PAN CH01 Edits User Defined Channel As...

Page 17: ...F Address Via DMX No DMX Status Hold Close Shutter Auto Program Auto Run If No DMX Pan Reverse ON OFF Pan Reverse Movement Tilt Reverse ON OFF Tilt Reverse Movement Pan Degree 630 540 Pan Degree Selec...

Page 18: ...01 SCxxx Program In Loop Program 10 Step 64 SCxxx Save and Exit Edit Scenes Scene 001 Scene 250 Pan Tilt Save and Automatically Return Fade Time Scene Time Manual Scenes Edit Input By Outside Stores...

Page 19: ...s like adjusting the DMX starting address are no longer needed This is especially useful when the device is installed in a remote area RDM ready and conventional DMX devices can be operated in one DMX...

Page 20: ...fine adjustments EFFECT ADJUST Calibration ONLY QUALIFIED TECHNICIANS SHOULD PERFORM THIS FUNCTION This function allows small adjustments to be made to the Pan Tilt and Zoom movements to compensate f...

Page 21: ...to If e g a Slave unit is set to Slave 1 in the menu Set to Slave the Master unit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Auto Program Part 2 To start an...

Page 22: ...he same program as the master units U J KK ENTER to confirm U J KK MODE ESC in order to return to the main menu 4 Program Selection for Edit Program U D L ZEdit Program U J KK ENTER to confirm U lect...

Page 23: ...a group of same model fixtures with varying usage times needs to be calibrated to match as much as possible Once a new White Balance preset is saved to the fixture the maximum dimmer intensity values...

Page 24: ...3 3 TILT MOVEMENT 8 BIT 0 255 TILT Movement 4 4 4 TILT MOVEMENT 16 BIT 0 255 Fine Control of TILT Movement 5 5 RED ALL LEDs 0 255 Red 0 Black 255 100 6 RED FINE ALL LEDs 0 255 Red FINE Adjustment 6 7...

Page 25: ...LED GROUP 1 0 255 Amber 0 Black 255 100 10 CYAN LED GROUP 1 0 255 Cyan 0 Black 255 100 11 VIOLET LED GROUP 1 0 255 Violet 0 Black 255 100 12 RED LED GROUP 2 0 255 Red 0 Black 255 100 13 GREEN LED GRO...

Page 26: ...104 135 From CYAN to BLUE 136 167 From BLUE to MAGENA 168 199 From MAGENTA to RED 200 231 From RED to WHITE 232 255 Crossfading Colors from SLOW to FAST 13 20 27 COLOR PRESETS 0 4 NO FUNCTION 5 9 WHI...

Page 27: ...utter OPEN LEDs ON 128 159 Pulse Effect In Sequences 160 191 Shutter OPEN LEDs ON 192 223 Random Strobe Effect SLOW to FAST 224 255 Shutter OPEN LEDs ON 16 23 30 DIMMER INTENSITY 0 255 Dimmer 0 to 100...

Page 28: ...ITE BALANCE 0 189 NO FUNCTION 190 254 EDIT a New WHITE BALANCE Setting 255 SAVE New WHITE BALANCE Setting to Fixture s NOTE DMX Value 91 93 must first be selected on CH24 Basic CH31 Stand or CH40 Exte...

Page 29: ...w w w e l a t i o n l i g h t i n g c o m 29 PLATINUM SEVEN User Manual L E D G R O U P S...

Page 30: ...rror message 01Er 02Er and 05Er flash repeated 5 times If an error does occur during the initial start up procedure the fixture will self generate a second reset signal and try to realign all the moto...

Page 31: ...during a reset function TILT The TILT movement is not located in the default position after the reset This message will appear after a fixture reset if the magnetic indexing circuit malfunctions sens...

Page 32: ...fer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points...

Page 33: ...UV 7 Colors Even and Smooth Color Mixing CONTROL CONNECTIONS 3 DMX Channel Modes 24 31 40 Adjustable Refresh Rate 900 1500 2500 4000 5000 10000 15000 20000 25000 Hz Adjustable Gamma Brightness 2 0 2 2...

Page 34: ...514 AMBER 2 222 206 1 930 179 1 470 137 972 90 660 61 CYAN 6 316 587 5 680 528 4 162 387 2 625 244 1 776 165 U V 65 6 54 5 40 4 25 2 18 2 FULL ON 38 500 3 577 34 100 3 168 24 860 2 309 15 860 1 473 11...

Page 35: ...without any prior written notice O P T I O N A L A C C E S S O R I E S ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp DRCPLAT7 Dual Road Case For PLATINUM SEVEN EWDMXSYSTEM Wire...

Page 36: ......

Reviews: