background image

2

 

©2020 ELATION PROFESSIONAL

 all rights reserved. Information, specifications, 

diagrams, images, and instructions herein are subject to change without notice. ELATION 
PROFESSIONAL logo and identifying product names and numbers herein are trademarks 
of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters 
of copyrightable materials and information now allowed by statutory or judicial law or 
hereinafter granted.    Product names used in this document may be trademarks or 
registered trademarks of their respective companies and are hereby acknowledged.    All 
non-ELATION brands and product names are trademarks or registered trademarks of their 
respective companies. 
 

ELATION PROFESSIONAL

 and all affiliated companies hereby disclaim any and all 

liabilities for property, equipment, building, and electrical damages, injuries to any persons, 
and direct or indirect economic loss associated with the use or reliance of any information 
contained within this document, and/or as a result of the improper, unsafe, insufficient and 
negligent assembly, installation, rigging, and operation of this product. 
 

Elation Professional USA | 

6122 S. Eastern Ave. 

Los Angeles, CA. 90040 

323-582-3322 

|

 323-832-9142 fax

 |

 

www.elationlighting.com 

|

 [email protected]

 

Elation Professional B.V

Junostraat 2 

6468 EW Kerkrade, The Netherlands 

+31 45 546 85 66 

|

 +31 45 546 85 96 fax

 

|

 

www.elationlighting.eu 

|

 [email protected] 

Elation Professional Mexico

 

AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000 

+52 (728) 282-7070 

 

 

 

D O C U M E N T   V E R S I O N  

Due to additional product features and/or 
enhancements, an updated version of this document 
may be available online. Please scan the QR Code with 
your mobile device or visit 

www.elationlighting.eu

 for the 

latest revision/update of this manual, before installation 
and/or programming. 
 

Date 

Document 

Version 

Software 

Version 

 

DMX 

Channel Modes 

Notes 

04/21/2020 

1.0 

1.03 

1 / 2 / 3 / 4 / 5 

Initial release. 

 

Summary of Contents for KL Fresnel 6 PO

Page 1: ...KL Fresnel 6 PO User Manual Black version C 50 M 50 Y 50 K 100 White version C 0 M 0 Y 0 K 0...

Page 2: ...or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installati...

Page 3: ...arranty USA Only 5 Safety Guidelines 6 Maintenance Guidelines 8 Fixture Overview 9 Installation Instructions 11 System Menu 13 Manual Dimmer Adjustment 16 DMX Channel Functions and Values 17 Dimmer Mo...

Page 4: ...rt Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Fixture Barn Door Assembly Junior Pin Gel Frame CUSTOMER SUPPORT Contact ELATION Service for any...

Page 5: ...t its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty sha...

Page 6: ...increase the risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING S...

Page 7: ...15cm between fixture and other devices or walls for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always install...

Page 8: ...n service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electrical che...

Page 9: ...2 Mounting Yoke 3 Clamp Mounting Point 4 Junior Pin installed 5 Tilt Adjustment Knob 6 Pan Adjustment Knob 7 Dimmer Adjustment Knob 8 Enter Button 9 Display Screen 10 Down Button 11 Up Button 12 Mode...

Page 10: ...10 F I X T U R E O V E R V I E W 15 Service Port 16 Fuse T3A 250V 17 Power In 18 Power Out 19 3 pin DMX In 20 5 pin DMX In 21 3 pin DMX Out 22 5 pin DMX Out...

Page 11: ...m matrix designs to any metal truss structure or placing the fixture s on any surface a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is prope...

Page 12: ...ate rating not included to the safety cable rigging point on the fixture RIGGING Overhead rigging requires extensive experience including calculating working load limits understanding the installation...

Page 13: ...menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that requires adjusting press the ENTER button...

Page 14: ...play 30 second screen saver On Off Key Lock On Off Flash display screen flashes when DMX conn is lost On Off Invert flip screen display On Off Temp C F C F Dim Mode Standard Stage TV Architec Theatre...

Page 15: ...Sw On Off DFSE On Off INFO Time Info Current fixture run time since last reset in hours Total total fixture run time in hours Last time since last time reset Password 050 60 Clear On Off Temp Info LED...

Page 16: ...t max power for 2 minutes This function is intended to aid the operator in adjusting the pan tilt and zoom of the fixture as desired When the fixture is not connected to DMX communication the Dimmer A...

Page 17: ...ntensity 0 to 100 2 000 255 Dimmer Intensity Fine 0 to 100 3 CH MODE Elation KL Fresnel 6 PO DMX Channels Functions 3 DMX Channels 3 CH Mode Supports Software Versions 1 03 CHANNEL VALUE FUNCTION 1 00...

Page 18: ...Standard Mode Supports Software Versions 1 03 CHANNEL VALUE FUNCTION 1 000 255 Dimmer Intensity 0 to 100 2 000 255 Dimmer Intensity Fine 0 to 100 3 Strobe 000 031 Closed 032 063 Open 064 095 Strobe S...

Page 19: ...Extended Mode Supports Software Versions 1 03 CHANNEL VALUE FUNCTION 1 000 255 Dimmer Intensity 0 to 100 2 000 255 Dimmer Intensity Fine 0 to 100 3 Strobe 000 031 Closed 032 063 Open 064 095 Strobe S...

Page 20: ...10 0 s 142 255 Default 5 Control hold for 3 seconds 000 100 Idle Refresh Rate 101 105 900 Hz 106 110 1000 Hz 111 115 1100 Hz 116 120 1200 Hz default 121 125 1300 Hz 126 130 1400 Hz 131 135 1500 Hz 13...

Page 21: ...D I M M E R M O D E S Select desired DIMMER MODE Standard Stage TV Architectural Theatre Stage2 Output 0 100 Output 0 100 Output 0 100 Output 0 100 DMX DMX DMX DMX LINEAR SQUARE INVERSE SQUARE S CURV...

Page 22: ...D CONTROL CONNECTIONS 5 DMX Channel Modes 1 2 3 4 5 DMX Support RDM Remote Device Management Adjustable Refresh Frequency 900 25 000 Hz 8 16 Bit Dimming Control 4 Button and 1 Dial Control Panel Manua...

Page 23: ...23 D I M E N S I O N A L D R A W I N G S FIXTURE WITH JUNIOR PIN INSTALLED Drawings not to scale...

Page 24: ...24 D I M E N S I O N A L D R A W I N G S BARN DOOR AND JUNIOR PIN INSTALLED Drawings not to scale...

Page 25: ...25...

Page 26: ...EU 1236100173...

Reviews: