background image

©Elation Pr

o

fessionals®  -  www.elationlighting.com  - Event Bar Instruction Manual Page 11

©Elation Pr

o

fessionals®  -  www.elationlighting.com  - Event Bar Instruction Manual Page 12

2. To activate Blackout press the UP or DOWN buttons until Yes 
is displayed, press ENTER to confim and exit. The fixture will 
now be in Blackout mode. To deactivate Blackout mode, select 
No and press Enter.

Back Light - With this function you can have the LED dis-

play turn off after 20 seconds.

1. Press the MENU button until “Back Light” is displayed, press 
ENTER.
2. The display will show either “ON”

 

or

 

“OFF”. Press the UP or 

DOWN buttons to select “ON” to keep the LED display On at all 
times, or “OFF” so that the LED display turns off after 20 sec-
onds. 
3. Press ENTER to confirm.

Manual Test - This function will let you manually test the 
pan, tilt, & dimmer of each light.

 

1. Tap the MENU button until “Manual Test” is displayed, press 
ENTER.
2. Use the UP and DOWN buttons to test the four lights. To exit 
manual test press either the MENU or ENTER button.

Auto Test - This function will run a self test program.

 

1. Tap the MENU button until “Auto Test” is displayed, press 
ENTER.
2. The fixture will now run a self test program. To stop the self 
test press the MENU  button.

Pan Inverse 

1. Tap the MENU button until “Pan Inverse” is displayed, press 
ENTER. Either “Inverse” or “Normal” will be displayed. 
2. To activate the Pan inversion tap the UP or DOWN buttons 

until “Inverse” is displayed, press ENTER to confim. To deacti-
vate Pan inversion, select “Normal” and press Enter.

Tilt Inverse 

1. Tap the MENU button until “Tilt Inverse” is displayed, press 
ENTER. Either “Inverse” or “Normal” will be displayed. 
2. To activate the Pan inversion tap the UP or DOWN buttons 
until “Inverse” is displayed, press ENTER to confim. To deacti-
vate Pan inversion, select “Normal” and press Enter.

Fixture Time - With this function you can display the run-
ning time of the unit.

1. Press the MENU button until “Fixture Time” is displayed, 
press ENTER.
2. The display shows the running time of the unit. Press MENU 
to exit.

Firmware Version - Use this function to display the Firm-
ware version of the unit.

1. Press the MENU button until “Firmware Version” is displayed, 
press ENTER.
2. The display will show the software version. Press MENU to 
exit.

Fixture Reset - Use this function to reset the unit.

1. Tap the MENU button until “Fixture Reset” is displayed, 
press ENTER.
2. The fixture will now reset.

 Event Bar   

 

 

  System Menu & Operation

 Event Bar   

 

 

  System Menu & Operation

Summary of Contents for EVENT BAR

Page 1: ...ture The Event Bar has 3 DMX Modes 12 Channel DMX Mode 14 Channel Mode and 25 Channel Mode The fixture three operating modes sound active mode show mode or DMX controlled The Event Bar can only be run as stand alone unit For best results use fog or special effects smoke to enhance the light projections Customer Support Elation Professionals provides a toll free cus tomer support line to provide he...

Page 2: ...sed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance Event Bar Safety Precautions Elation Professionals www elationlighting com Event Bar Instruction Manual Page 4 Elation Professionals www elationlighting com Event Bar Instruction Manual Page 3 3 DMX Channel Modes 12 Channel Mode 14 Channel Mode 25 Channel Mode 2 Operating Modes Show ...

Page 3: ...pproved DMX 512 110 Ohm Data cable for data input and data output We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy...

Page 4: ...XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting stan dard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a proper cable conversion Conductor 5 Pin XLR Male In 3 Pin XLR Female Out Pin 1 Pin 5 Do Not Use Pin 4 Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Da...

Page 5: ...ENU button until Channel Mode is displayed press ENTER Either 12 Channel Mode 14 Channel Mode or 25 Channel Mode will be displayed 2 Press the UP or DOWN buttons to choose your desired DMX mode and press ENTER to confim and exit Slave Mode This will let you set the unit as a master or slave in a master slave configuration 1 Press the MENU button until Slave Mode is displayed press ENTER Either Mas...

Page 6: ... 2 The fixture will now run a self test program To stop the self test press the MENU button Pan Inverse 1 Tap the MENU button until Pan Inverse is displayed press ENTER Either Inverse or Normal will be displayed 2 To activate the Pan inversion tap the UP or DOWN buttons until Inverse is displayed press ENTER to confim To deacti vate Pan inversion select Normal and press Enter Tilt Inverse 1 Tap th...

Page 7: ...in With this feature you can connect the fixtures to one another using the IEC input and output sockets The quantity that can be connected is 4 fixtures maximum After 4 fixtures you will need to use a new power outlet They must be the same fixtures DO NOT mix fixtures Event Bar Home Position Adjust With this function you can adjust and set the fixtures home position 1 Press the ENTER button for at...

Page 8: ...s www elationlighting com Event Bar Instruction Manual Page 15 Elation Professionals www elationlighting com Event Bar Instruction Manual Page 16 Event Bar 25 Channel Mode Event Bar 12 Channel Mode Event Bar 14 Channel Mode ...

Page 9: ...n Professionals concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professionals factory unless prior written authorization was issued to purchaser by Elation Profes sionals if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and...

Page 10: ...e design of this unit and this manual are subject to change without any prior written notice Event Bar Specifications Model Event Bar Voltage 100 240V 50 60Hz LEDs 4 x 3W White LEDs Beam Angle 12 Degrees Optional 6 Degree Lens Power Consumption 54W Fuse 7A Power Cord Daisy Chain 4 Fixtures Max Dimensions 39 L x 3 W x 8 H 1000mm x 80mm x 202mm Weight 16 8 Lbs 7 6 kgs Colors White Duty Cycle None DM...