background image

 
 

w w w . e l a t i o n l i g h t i n g . c o m    

 

 

   

                    1

                                                   

CUEPIX   BLINDER   WW2

™   

User   Manual   1.0

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 

CUEPIX BLINDER WW2™ 

user manual 1.0 

EL

A

TI

O

N

 

|

 

CU
EP

IX

 B

LIN

D

ER

 W

W

2

 

|

 

us

e

r m

a

n

ua
l 1

.0

 

Summary of Contents for CUEPIX BLINDER WW2

Page 1: ...w w w e l a t i o n l i g h t i n g c o m 1 CUEPIX BLINDER WW2 User Manual 1 0 CUEPIX BLINDER WW2 user manual 1 0 E L A TI ON CUEPIX BLINDER WW2 user manual 1 0 ...

Page 2: ...uct names are trademarks or registered trademarks of their respective companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the im...

Page 3: ...on Professional Every CUEPIX BLINDER WW2 has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or par...

Page 4: ...arranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice It...

Page 5: ...s set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professional will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Pro...

Page 6: ...lation of this fixture and only the original rigging parts brackets holders clamps safety cables included with this fixture should be used for installation Any modifications will void the original manufactures warranty and increase the risk of damage and or personal injury Never look directly into the light source of this fixture to prevent risk of injury to your retina which may induce blindness ...

Page 7: ...e This fixture is a professional lighting effect designed for use on stage in nightclubs theatres etc Do not attempt installation and or operation without proper knowledge of how to do so Do not permit operation by persons who are not qualified for operating this type of theatrical fixture Most damages are the result of operations by nonprofessionals If this fixture is exposed to extreme temperatu...

Page 8: ...ion to next unit 6 3pin DMX OUT Sends DMX signal to next fixture in chain via a female 3pin XLR jack 7 5pin DMX OUT Sends DMX signal to next fixture in chain via a female 5pin XLR jack 8 LCD Menu Control Display LCD menu control display 9 ENTER Button Used to enter into or lock a certain menu function 10 DOWN Button Used to toggle down or back through the menu functions and settings 11 UP Button U...

Page 9: ...10 times the weight of the fixture 51Kgs 112 Lbs Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing the fixture When power linking multiple units 5pcs Max for 120V and 11pcs Max for 220V MOUNTING POINTS Overhead mounting requires extensive experience including a...

Page 10: ...ress and hold MODE button for approx 10 seconds to unlock display MANUAL DIMMING FLASH Select the Manual Dimming by pressing UP DOWN buttons until DIMMER C1 99 is displayed and then press ENTER button then select desired Dimming Value for COB Module 1 0 99 by pressing UP DOWN buttons and press ENTER button and DIMMER C2 99 is displayed and then select desired Dimming Value for COB Module 2 0 99 by...

Page 11: ...ed Dim Curve Standard default Stage TV Architectural or Theatre SLAVE MODE Link the units via DMX cable and then set each of the Salve units to SLAVE mode by pressing MODE button and selecting SLAVE MODE and the slave units will operate in accordance with the Master unit DMX MODES Channel Modes 1CH 2CH 3CH 4CH 1 Channel Mode Both COB Module Sections Channel Value Function 1 000 255 Master Dimmer 0...

Page 12: ... 41 42 84 85 127 128 170 171 213 214 255 Dim Curves Standard Stage TV Architectural Theatre Default To Unit Curve setting 4 Channel Mode Channel Value Function 1 LEFT COB MODULE 000 255 Master Dimmer 0 100 2 RIGHT COB MODULE 000 255 Master Dimmer 0 100 3 000 255 Flash From Slow To Fast 4 0 41 42 84 85 127 128 170 171 213 214 255 Dim Curves Standard Stage TV Architectural Theatre Default To Unit Cu...

Reviews: