For detailed wiring instructions, please refer to the Integration Note and documentation for 
the connected device.

8. LAN / PoE Connection

The EL-IO-200 can be powered over Ethernet (PoE).The minimum PoE requirement is IEEE 
802.3at. 42.5 - 57 VDC, 600 mA maximum.

Note:

 The EL-IO-200 can be connected via WiFi, however a wired connection is preferred.

9. Reset Button

Press and hold the reset button for 3 to 5 seconds to reset the network settings. The IP 
address will be reset to DHCP if a static IP address has been assigned and if configured for 
WiFi, will reset to an Ethernet connection.

10. Power

Once all other connections have been completed, connect an Ethernet cable connected to a 
PoE switch or the 5 VDC, 2A power supply to the DC input.

11. LED Status Indicator

The LED communicates the status of the controller:

Blue

Power on / connected to network / connected to main controller

Flashing Blue

Power on / connected to network / NOT connected to main controller 

Summary of Contents for EL-IO-200

Page 1: ...Quick Install Guide EL IO 200 Control Extender ...

Page 2: ... of the FCC rules and with Canadian ICES 003 and RSS 247 Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Cet appareil numérique de classe B est conforme aux normes canadiennes ICES 003 et RSS 247 Son fonctionnement est soumis aux deux ...

Page 3: ...tallation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circ...

Page 4: ... 7 3 RS 232 Serial Connections 9 4 RS 485 Serial Connections 10 5 IR Output Connections 10 6 Signal Input Connections 11 7 Relay Connections 11 8 LAN PoE Connection 12 9 Reset Button 12 10 Power 12 11 LED Status Indicator 12 12 Network Connection 13 13 Specifications 13 ...

Page 5: ...ains valuable hardware and software reference documentation and is considered an important supplement to this document Make sure you have the latest version by visiting the ELAN Dealer website at www elancontrolsystems com and follow the Dealer Resources link Included in the box 1 EL IO 200 Control Extender 1 5V DC Power Supply 2 Male DB9 to female RJ45 adapter 1 Female DB9 to female RJ45 adapter ...

Page 6: ...tputs 4 discreet IR ports 12V Compatible with Xantech single and dual emitters Signal Inputs 2 signal input ports Detect contact closure or voltage input to trigger events Detects 5 24VDC 24VAC Max Relay Connections 2 relays 12VDC 24VAC 1A Ethernet Connection 10 100 Mbps PoE IEEE 802 3at af 48VDC 600mA Reset Resets the IP address to DHCP Power Connector DC power input 5V 2A ...

Page 7: ...bracket Wall Mounting The EL IO 200 chassis has been designed to allow convenient wall mounting in any ori entation Arrows on the rear panel may be used to mark the location for the screws Mark the screw locations mount the screws leaving approx 3 16 5mm of screw exposed and slide the chassis over the screws 2 Mounting 8 46in 215mm 5in 127mm 3in 76 2mm ...

Page 8: ...properly manage connected wiring so that there is no tension on the connections Structured Wiring Cabinet Mounting Mount the EL IO 200 in a structured wiring cabinet using the optional structured wiring cabinet mount 1 Attach mounting bracket to the wiring cabinet with snap rivets and washers 2 Snap the controller to the 2 hooks on the mounting bracket ...

Page 9: ... table shows the 568A and 568B color codes and the function of each conductor of the RS 232 ports Please refer to the ELAN Integration Note for the specific device to deter mine the proper RJ45 to DB9 adapter to use CAUTION Do not connect cables with PoE power on them to the RS 232 or RS 485 ports as it will damage the unit RS 232 Port Pin 586A Color Code 586B Color Code 1 White Green White Orange...

Page 10: ...grating for wiring and programming specifics CAUTION Do not connect cables with PoE power on them to the RS 232 or RS 485 ports as it will damage the unit 5 IR Output Connections Four discrete IR outputs are supplied to control third party devices Each output is compati ble with Xantech single and dual emitters IR outputs are 12V RS 232 Port Pin 586A Color Code 586B Color Code Naming Conventions 1...

Page 11: ... DAMAGE THE EL IO 200 For detailed wiring instructions please refer to the Integration Note 7 Relay Connections Two normally open relays are available for controlling third party devices motorized lifts window shades and projection screens The included removable connectors will accept up to 16ga bare copper leads Be careful to verify that no portion of one wire touches the other wire Prior to conn...

Page 12: ...nd hold the reset button for 3 to 5 seconds to reset the network settings The IP address will be reset to DHCP if a static IP address has been assigned and if configured for WiFi will reset to an Ethernet connection 10 Power Once all other connections have been completed connect an Ethernet cable connected to a PoE switch or the 5 VDC 2A power supply to the DC input 11 LED Status Indicator The LED...

Page 13: ...l Input 2 Terminal Block Connectors 3 pin Relay 2 Terminal Block Connectors 3 pin Ethernet PoE IEEE 802 3af 802 3at Type 1 1 RJ 45 port Power 1 Coaxial Type A 2 5mm inside diameter 5V 2A 2 4 5 GHz WiFi 802 11 b g n ac System Software compatibility Refer to the integration note for compatibility Updates managed by ELAN Core Module software General Operating Temperature 0 to 40 C Operating Humidity ...

Page 14: ...QUICK INSTALL GUIDE 14 Notes ...

Page 15: ...EL IO 200 15 Notes ...

Page 16: ...th respect to equipment sold by but not manufactured by NSC the warranty obligations of NSC shall in all respects conform to the warranty actually extended to NSC by its supplier The foregoing warranties do not cover reimbursement for labor transportation removal installation or other expenses which may be incurred in connection with repair or replacement Except as may be expressly provided and au...

Reviews: