Integration Note
Manufacturer:
DSC
Model Number(s):
MAXSYS Series
Core Module Versions:
4.0 (all builds)
Comments:
Document Revision Date:
1/30/2013
O
VERVIEW AND
S
UPPORTED
F
EATURES
The
DSC MAXSYS Series
panels integrate with the
g!
system using an RS-232 serial connection. The
panel requires the PC4401 Data Interface Module to provide the RS-232 connection to the panel.
Integration of the security system provides monitoring and control from any touch screen, telephone or
computer both locally and remotely. Additionally, events occurring in the security system can trigger
system commands in other sub-systems in the home. For example, a burglar alarm can turn all the lights
on and send out email alerts. The security system can also receive commands as a result of events
within other sub-systems. For example, changing the house mode from Home to Vacation can trigger a
security command to arm the system.
IMPORTANT! This panel requires the PC4020 chip on the main circuit board be version 3.5 or
higher to properly communicate with g!.
Due to possible compatibility issues, the DSC MAXSYS should only be used on COM ports 1 and 2
of the HC-Series System Controllers.
T
HESE PANELS SUPPORT THE FOLLOWING FEATURES
:
Arm – Disarm:
Arm and disarm from the Viewer interface is supported. Status information is available for
all partitions.
Auto Arm:
Arming as a System Command from the Event Mapper is supported. By default, automatic
arming is disabled in the Configurator.
Zone Status:
Zone status information is available for all zones (in any partition), and is properly shown in
the Viewer.
Zone Bypass:
Zones can be bypassed from the
g!
interface.
History View:
The history view is properly supported on any Viewer.
Auto Partition Detection
: All available partitions are automatically detected.
Auto Zone Detection
: After a zone has been faulted the
g!
system will automatically detect the zone
number and partition number, but it will not detect the zone name.
T
HESE PANELS DO NOT SUPPORT THE FOLLOWING FEATURES
:
Auto Name Detection:
Zone and partition names cannot be read from the panel.
Arm in Stay Mode:
The DSC MAXSYS panels can only be armed in
Away
mode from the
g!
interface:
due to a limitation in the DSC RS-232 protocol, it is not possible to arm the panel in
Stay
mode.
Any feature not specifically noted as supported should be assumed to be unsupported.