Specifications could be modified without any notification. Non-contractual document.
Copyright © 2018 ELA Innovation
User Guide SCIEL
READER IP2 04B.docx
8/18
3.5
Reset button
Figure 9:
Reset button surrounded by the red rectangle
To
reset the Ethernet module
to factory
settings,
plug a power supply
into the reader,
and
press the Reset button
for 10 seconds.
It does NOT reset the reader itself!
To access the Reset button, you have to unscrew the 4
screws on the top of the housing, as shown on the image
alongside.
Image 10:
4 screws to be unscrewed
3.6
DIN rail mounting
The SCIEL Reader IP2 can be mounted on a standard DIN rail.
To do this, you need our DIN CLIP 01 accessory, a screwdriver and a 3mm hex key.
Open the reader’s housing by
unscrewing the 4 screws on the top (see image above).
Figure 11:
Main board’s screws
First, unplug all the power supplies and other
cables from the reader.
Unscrew the 2 screws that block the main board.
Figure 12:
DIN rail screws
Remove carefully the main board and pick the 2 screws up.
Keep them for the following operations