El.Mo HERCOLA User Manual Download Page 16

16

For more information: paragraph 2.5.11 

p. 12.

Such user change can be disabled during configuration.

5.6    Advanced  settings

The installer can set advanced settings using BrowserOne 

software.

5.6.1    Dialler block at disarming

Users can require to block phone communications (voice 

and digital) caused by sectors disarming.

This function is available in 

System Options

 menu in 

BrowserOne.

If dialler block is removed, the phone dialler will activate 

when the first event generated after the removal occurs.

5.6.2   Limits to dialler activations

Installers can program the control unit so that it limits the 

number of events that trigger the dialler.

When the max number is reached, the voice/SMS dialler ig-

nores other calls until the next day.

This function is available in 

Telephone Dialler

 menu in 

BrowserOne.

Limits refer to events, and not to calls: the amount of 

calls can be higher if events cause several calls. More-

over, the limit refers only to voice dialler and not digital 

dialler.

For 

Low battery

 and 

No Supervision

 events a limit to the 

number of calls they may generate (both voice and digital) 

can be set using the software application.

In addition, such events will activate the dialler only if there 

are no discharged battery memories for the relevant device.

5.6.3   Disable arm/disarm commands

Installers can disable arm/disarm commands via SMS texts 

or voice communications (not digital ones) for each single 

user.

This function is available in 

Users

 menu in BrowserOne.

6  

 TEMPERATURE  MONITORING

HERCOLA series units are equipped with a temperature de-

tector measuring the temperature inside the housing.

6.1    Temperature  thresholds

The installer can set two thresholds, one minimum and one 

maximum:

•   when the temperature goes from minimum to maximum 

threshold the "Maximum Temperature" event will be 

generated.

•   when the temperature goes from maximum to minimum 

threshold the "Minimum Temperature" event will be 

generated.

Such events can be used to activate the on-board relay or 

an external one.

6.2    A-B temperatures management

A more advanced temperature control can be re-

alised using output functions and alarm/pre-alarm 

thresholds (in 

BrowserOne

: page Temperature, tab 

Management of A-B temperatures

).

The installer can set four thresholds with corresponding 

events: two for high temperature (Pre-alarm A and Alarm A), 

and two for low temperature (Pre-alarm B and Alarm B.)

The installer can set an output to activate when the temper-

ature reaches one of the thresholds and to reset when the 

temperature falls again within threshold ranges set.

If the temperature is not over/under thresholds set, the out-

put can be reset also by users in the two following ways:

It is required the installer has set one output with 

Control of A-B temperatures

 function associated to a 

SX

 sector key.

Reset from keypad

 

– Key in user code.

 

– Press SX sector key.

Reset via SMS

 

– Send SMS command 

S.X

 (see chapter 10 

p. 21).

Example

If S3 key has been associated to the function, the output will 

reset:

•   with the user code keyed in and followed by S3 key, or

•   sending an SMS text with 

S.3

6.3    Calibration

The temperature detected by the sensor is affected by 

the heat generated by electronic components inside the 

housing.

For a correct detection, it may be necessary to calibrate the 

detector.

Use 

TEMP CALIBR. 

 option in user menu (see paragraph 

2.5.7 

p. 11).

If the temperature displayed is x°C below environment tem-

perature, set a + x°C adjustment.

If the temperature sensor has not been calibrated, the 

Summary of Contents for HERCOLA

Page 1: ...plastic housing Icons used in this manual Example of messages on keypad display FRI 21 4 21 7 01 06 18 09 00 S1 S2 S3 S4 Area 1 Keys typing Usage example Manual contents Keypads usage chap 2 p 2 Oper...

Page 2: ...e associated to sector groups Each sector key provides information about arming status of corresponding sectors Key status Indication OFF All sectors associated to the key are disarmed ON All sectors...

Page 3: ...ection is enabled in BrowserOne all status indications from LEDs will be disabled Acoustic signalling for tampered zones The unit can be configured to emit a single or continued acoustic signal Din Do...

Page 4: ...module right temperature detected by the unit detector 21 4 21 7 The two indications can be inverted and the display of the built in temperature detector can be disabled Temperature values will blink...

Page 5: ...here is pending information the two arrows on the dis play will blink 2 3 4 SIM Balance status If the unit is equipped with a prepaid card the balance can be displayed on keypad Go to GSM STATUS Press...

Page 6: ...c tors proposed to the user With 4 areas 4 sectors mode each sector key is associated to a sector distinctively U U U U U U default 111111 SELECT SECTORS S1 S2 S3 S4 Area 1 FRI 21 4 21 7 01 06 18 09 0...

Page 7: ...Press numeric keys from 1 to 9 A 0 B C The single sector selection is not available for D E F and G sectors Example If sectors proposed for arming at the beginning are 1 2 3 6 and 7 Arm 123 67 when y...

Page 8: ...per area mode if checked during system configuration to do so press sector key OK or press sector key twice as ex plained in the previous paragraph 2 4 5 p 7 Sectors associated to that sectors key wi...

Page 9: ...rinclusionwith and one of the following events occur system control devices serial devices tamper dialler siren battery fault the installer code will be required to force system arming INSTALLER CODE...

Page 10: ...keypad direct connection or remote assistance The user can use the following menu Use arrow keys or to go to INSTALLER AUTH option Press OK to enter the menu Press 2 to select TEMPORARY only once wit...

Page 11: ...to exit the menu without saving Daily schedules setup Use arrow keys or to go to CHRONOTHERMOSTAT option Press OK to enter the menu Use arrow keys or to browse among daily schedules Press OK to enter...

Page 12: ...erty the message NOT EXECUTAB will appear The system shows the first zone to be tested which will be alarmed The system beeps for confirmation and is now ready to test the following zone Repeat the p...

Page 13: ...e than 20 at tempts are detected non recognised keypad key re mote control remote access codes the event Maximum access attempts exceeded will be generated More consecutive access attempts with the sa...

Page 14: ...ol unit detects unauthorised access attempts if within a arming disarming cycle more than 20 at tempts are detected non recognised keypad key re mote control remote access codes the event Maximum acce...

Page 15: ...on the phone keypad 5 The call is interrupted the unit will call the following number if set 0 The call is interrupted the unit will not call other numbers until a new event occurs or It activates re...

Page 16: ...holds The installer can set two thresholds one minimum and one maximum when the temperature goes from minimum to maximum threshold the Maximum Temperature event will be generated when the temperature...

Page 17: ...are it will be possible to see its interface on unit display To switch from intrusion to chronothermostat interface Press OK Press 0 Press OK The control unit can be set to display chronothermostat in...

Page 18: ...s 7 1 2 Temperature change Temperature values set can be changed afterwards The change can be manual or temporary Manual change In chronothermostat interface in idle mode Use arrow keys or Press 1 rep...

Page 19: ...o control an air conditioning The install shall enable the specific function via software In summer mode boiler block detection is disabled remote control SMS texts indicate air conditioning in stead...

Page 20: ...the property is reset On the contrary the Weekly Programmer Max Security prop erty is reset by Max Security Set and Max Security Reset weekly programmer functions only In detail if a sector is armed...

Page 21: ...r Max Security property 10 REMOTE INTERROGATION AND REMOTE CONTROL When control units are equipped with GSM module SMS can be used to receive information about system status to send commands to the un...

Page 22: ...he following 4 messages PANEL DISARMED ready to be armed All sectors authorised for the user are disarmed but can be armed PANEL DISARMED not ready to be armed All sectors authorised for the user are...

Page 23: ...at report The control unit replies with an SMS text containing the unit internal temperature measured by the sensor Replying SMS XX X degrees Temperature detected if single ext XX X degrees int XX X d...

Page 24: ...rised for Small Maintenance N DENIED Zone inclusion is not allowed or the user is not au thorised for Small Maintenance 10 3 7 Output commands Replying SMS COMMAND S EXECUTED The command has been exec...

Page 25: ...t One sensor or more is not powered correctly Power voltage is below set threshold ANOMALY Sound low volt One siren or more is not powered correctly Power voltage is below set threshold ANOMALY R C Lo...

Page 26: ...Function keys p 14 4 2 Operation with remote controls p 14 4 2 1 System arming p 14 4 2 2 Disarming p 14 4 2 3 Disarming with duress mode p 14 4 2 4 Panic event p 15 4 2 5 System forced arming p 15 5...

Page 27: ...27 GENERAL WARNINGS P 28 INSTALLER WARNINGS P 28 USER WARNINGS P 28 MAIN SAFETY RULES P 28 DISPOSAL WARNINGS P 28...

Page 28: ...es Certain products include batteries re chargeable or otherwise as an emergency backup power supply If connected incorrectly they may cause damage to the product or prop erty and may endanger the ope...

Reviews: