STEP 2

Optional Step 2.1 (Using the Front and Bottom Radiator – 

GREEN

)

Install the following in this sequence: EK-Quantum Torque Extender 
Rotary MF 14mm, EK-Quantum Torque Angled – 90°, and EK-
Quantum Torque HTC fitting on the radiator port closer to the 
distribution plate. EK-Torque HTC fittings should be installed on the 
other radiator port and the bottom two distribution plate holes. 

Optional Step 2.2 (Using the Front Radiator Only – 

RED

): 

  

Execute the previous “

GREEN

” steps with an additional EK-Quantum 

Torque Extender Static MF 28mm for the radiator port further from 
the distribution plate.

After either of these steps, push the radiator on the bracket with 
ports on the bottom, as seen in the image. Make sure you cut the 
tubes just right, with the position of the radiator matching the 
screw holes on the metal bracket. We suggest the shorter tube be 
51 mm and the longer one 107 mm. Once you’re finished with the 
placement, tighten the radiator screws.

Important: 

Optional steps apply when using EK-

Quantum Surface P360 or P240 radiators, or in case of 
S360 and S240 radiators when extra 14 mm extenders on 
both radiator ports are needed.

STEP 2

TORQUE ROTARY 
90° FITTING

14mm EXTENDER

28mm + 14mm 
EXTENDER

FITTING

Summary of Contents for EK-Quantum Reflection2 PC-O11D EVO D5 PWM D-RGB

Page 1: ...USER GUIDE DISTRIBUTION PLATE EK Quantum Reflection2 Torrent DDC 4 2 PWM D RGB Plexi...

Page 2: ...ty for any damages to the product and incidental consequential or indirect damages incurred due to improper or inappropriate installation Beforeyoustartusingthisproduct pleasefollowthesebasicguideline...

Page 3: ...THE FRACTAL TORRENT CHASSIS 8 PREPARING THE EK Quantum Reflection2 Torrent DDC 4 2 PWM D RGB DISTRIBUTION PLATE 9 INSTALLING THE EK Quantum Reflection2 Torrent DDC 4 2 PWM D RGB DISTRIBUTION PLATE INT...

Page 4: ...D RGB Plexi Metal Radiator Bracket IDENT 106328 M4 x 8 DIN7991 Screw 2 pcs M4 x 6 DIN7984 Screw 2 pcs M4 x 4 DIN7984 Screw 6 pcs M4 x 0 8 Metal Washer 2 pcs 2 5 mm Allen Key 1 pc EK Loop Multi Allen...

Page 5: ...PLATE DIMENSIONS 14 mm 56 8 mm 91 6 mm 111 9 mm 132 2 mm 161 6 mm 181 9 mm 202 2 mm 230 2 mm 258 2 mm 312 mm 333 mm 62 mm 62 mm 72 mm 80 4 mm 90 3 mm 118 3 mm 145 6 mm 40 4 mm 31 4 mm 27 4 mm 27 4 mm...

Page 6: ...1 2 105694 Inox Backplate 1 3 105690 TOP Plexi Lid part 1 4 3831109837580 EK DDC 4 2 PWM 12V SATA 1 5 5154 OR 52 x 3 NBR50 1 6 9018 Screw M4 x 25 DIN7984 4 7 8207 Screw M4 x 14 DIN7991 33 8 101556 LED...

Page 7: ...them outside the case If you are installing a bottom radiator remove all fans from the bottom of the case Otherwise you just need to remove the one closest to the front panel Before inserting the EK...

Page 8: ...need Important These steps are to be followed if you are using the EK Quantum Surface P240 radiator and hard tubing 360mm or longer radiators cannot be used in the bottom of the chassis when EK Quant...

Page 9: ...rackets STEP 3 PREPARING THE EK Quantum Reflection2 Torrent DDC 4 2 PWM D RGB DISTRIBUTION PLATE STEP 1 STEP 1 Take the metal radiator bracket and tighten it on the EK Quantum Reflection2 Torrent DDC...

Page 10: ...rque Extender Static MF 28mm for the radiator port further from the distribution plate After either of these steps push the radiator on the bracket with ports on the bottom as seen in the image Make s...

Page 11: ...4 screws to tighten the distribution plate STEP 2 INSTALLING THE EK Quantum Reflection2 Torrent DDC 4 2 PWM D RGB DISTRIBUTION PLATE INTO CHASSIS STEP 1 A Tilt the whole distribution plate assembly so...

Page 12: ...one 90 tube from the distribution plate to the radiator We suggest the straight tube be 93 5mm long and match its end with the 90 tube Then you can push the tubes into radiator ports and tighten the...

Page 13: ...ed ports must be closed with the supplied plugs using the EK Loop Multi Allen Key If one of the prescribed components will not be installed eg bottom radiator or GPU water block then one INLET and one...

Page 14: ...14 FLOW DIAGRAM DESIGNATED DRAINAGE HOLE...

Page 15: ...G THE PUMP The EK DDC 4 2 PWM pump has two connectors 1 SATA Connector It must be connected directly to your PSU at all times since it powers the pump 2 4 Pin PWM Fan Connector It can be connected to...

Page 16: ...he pump toaPSUoutsideyoursystem Donotconnectpowertoanyoftheother components Turn on the PSU and let the pump run continuously It is usual for the coolant level to drop during this process as air colle...

Page 17: ...fications and Product Parts where you can find the EAN number of each part you might need Mounting Mechanism EAN can be found under the Box Content section of this manual Include the EAN number and de...

Reviews: