background image

INSTALLATION MANUAL

PUMP

EK-Quantum 

Inertia D5 PWM

Summary of Contents for EK-Quantum Inertia D5 PWM

Page 1: ...INSTALLATION MANUAL PUMP EK Quantum Inertia D5 PWM ...

Page 2: ...eatwww ekwb comforupdates Before you start using this product please follow the basic guidelines Carefully read the manual before beginning with the installation process EK Fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured with the rubber o ring gaskets The use of quality market proven corrosion inhibiting coolants is always strongly recom...

Page 3: ...shers 5 pcs Protective Sticker 1 pc MOUNTING MECHANISM Bag content is universal you may not need every screw EK Quantum Inertia ALREADY DONE BY EK INSTALLING THE PUMP 60x3 O ring Gasket EK D5 PWM G2 Motor Locking Ring Rubber Damper Pump Holder M3 x 12 DIN7984 ...

Page 4: ...d into the pump holder push the assembled part onto the EK D5 PWM G2 Motor 6 Take the M3x12 DIN7984 screws and secure the EK D5 PWM G2 Motor to the pump holder You should use the 2mm Allen Key The plate with two M3 thread holes is preinstalled by EK INSTALLING EK QUANTUM INERTIA D5 PWM D RGB 64 34 By default the EK Quantum Inertia D5 PWM D RGB ships with a pump holder that can be installed directl...

Page 5: ...ia D5 PWM D RGB can be used in any mounting configuration position apart from being mounted upside down Mounting the pump upside down will result in the pump running dry and eventually lead to premature failure of the pump ...

Page 6: ...acket is sold separately If you have an option to mount the assembly on 120 140mm fan or 120 140mm fan mounting holes EK recommends using the EK Loop UNI Pump Reservoir Bracket Secure the EK Quantum Inertia D5 PWM D RGB onto the EK Loop UNI Pump Reservoir Bracket using the enclosed M4 x 10 DIN7984 screws and M4 PVC washers as shown in the image ...

Page 7: ...ng please use hose clamps or an appropriate substitute It is mandatory to use the correct INLET and OUTLET ports The OUTLET is the G1 4 threaded opening on the side of the pump top housing The INLET suction port is the central G1 4 threaded opening on the EK Quantum Inertia D5 PWM D RGB front face plane Make sure not to use fittings or barbs with a G1 4 thread longer than 5mm All EK fittings are c...

Page 8: ...onnected directly to your PSU at all times as it s used to power the pump 2 4 Pin PWM Fan Connector Can be connected to your motherboard s CPU fan or designated water pump header as well as a controller This cable is used to control and report the rotational speed of the pump If it s not connected the pump will run at its maximum speed 100 PWM ...

Page 9: ...B LED light to D RGB HEADER on the motherboard The LEDs will work if the pin layout on the header is as follows 5V Data Empty Ground Please ensure that the arrow indicated on the connector is plugged into the 5V line as indicated on your motherboard Failure to do so will damage your motherboard or the LED strip ...

Page 10: ...ide of your system Do not connect power to any of the other components Turn on the PSU and let the pump run continuously It is usual for the coolant level to drop during this process as air collects in the distribution plate Inspect all parts of the loop and in case the coolant leaks fix the issue and repeat the testing process Ensure that all hardware is dry before the system is powered on to pre...

Page 11: ...For assistance please contact http support ekwb com EKWB d o o Pod lipami 18 1218 Komenda Slovenia EU SUPPORT AND SERVICE SOCIAL MEDIA ...