background image

TWINSPOT IP65 EMERGENCY INSTALLATION INSTRUCTIONS

8

12. WIRELESS DAUGHTERBOARD

13. SELF TEST/ STANDARD WIRING/ CENTRAL BATTERY SYSTEM

The Twinspot inverter also supports an optional wireless daughterboard. The driver must be disconnected 
from mains and battery must be removed, before installing or changing any expansion module. More 
information and a list of other accessories can be found in the 

Wireless design and installation guide. 

The 

assembly for this part onto the inverter is shown below:

The inverter can be used in an automatic self-test mode which reduces the need for a test switch timer.
The self-test ability automatically disables if the unit is wired to DALI or the wireless daughterboard is attached.
Additionally the third generation platform can be wired to a central battery system. With this wiring the system 
cannot report the light status (see

 Self test support 

document for more information).

Figure 7: Daughterboard assembly diagram

Figure 8: Inverter standard wiring diagram

2

1

Wireless daughterboard (6118)(optional)
Twinspot inverter (1231, 1248, 1249, 1250)

1
2

Installer wired

Prewired

Summary of Contents for 1706

Page 1: ...06 EV TWINSPOT WP 1708 EV TWINSPOT WP PRO 1707 EV TWINSPOT WP PRO B 1709 EV TWINSPOT WP ULTP B 1 Welcome Overview Safety warnings Installation Mounting Range of movement Terminal block wiring Maintaining your Twinspot Replacing the battery Battery life Power and battery charge Wireless daughterboard Self test standard wiring central battery system DALI wiring central battery system Using the inver...

Page 2: ...ttery Smart battery conditioning to ensure the best performance from the battery 450V Electrolytic capacitors which increase the products reliability Highly efficient design to reduce fatigue on the product For buildings requiring longer durations such as 3 4 and 8 hours the installer can change the jumpers found on the unit for automatic scaling of the output Moreover should you require non maint...

Page 3: ... replacement If the product is satisfactory proceed with the installation 2 To mount the Twinspot the cover MUST be removed Remove the cover by unscrewing the cover screws using a large flat blade screwdriver Then pull the cover off as shown below 3 The cover is to be removed for mounting the Twinspot also battery replacement and servicing All installation options can be found in the following sec...

Page 4: ... 3 Mount the Twinspot by fastening screws securely to a flat surface as shown below Use supplied soft washer to waterproof the Twinspot and then put the cover back in place to finish mounting SURFACE MOUNT Figure 2 Surface mount installation Figure 2 Twinspot headlight adjustment 4 M4 cap screw locknut detail 6 RANGE OF MOVEMENT The Twinspots headlight range varies whether it is adjusted horizonta...

Page 5: ...overage of the beam Figure 3 Twinspot headlight horizontal range of movement Centre of rotation Centre of rotation 45 22 5 22 5 45 Figure 4 Twinspot headlight upward range of movement Centre of rotation Headlight tilt max 40 Figure 5 Twinspot headlight downward range of movement Centre of rotation Headlight tilt max 40 ...

Page 6: ...s to release the battery from its mounting position 4 Replace the battery as was previously installed and then secure with cable ties 5 Replace the Twinspot back into its previously mounted ceiling position and ensure the green charge light is illuminated Allow a few minutes for the battery to charge 6 Allow a minimum 24 hours charging time before carrying out any discharge tests as per the requir...

Page 7: ...eded The Ektor Generation III platform uses smart battery charging technology which reduces power consumption and increases battery life During the first stage of operation the battery charger charges the battery until full Afterwards the unit goes into a stage which charges the battery periodically This reduces the battery temperature and reduces the loss of electrolytes which ultimately increase...

Page 8: ...r this part onto the inverter is shown below The inverter can be used in an automatic self test mode which reduces the need for a test switch timer The self test ability automatically disables if the unit is wired to DALI or the wireless daughterboard is attached Additionally the third generation platform can be wired to a central battery system With this wiring the system cannot report the light ...

Page 9: ...ough DALI When used as a central battery system the devices can be tested with DALI A mains rated switch can be wired with this product to turn ON OFF the non emergency light in normal use This does not affect operation in emergency mode A mains rated sensor can be wired with this product to turn ON OFF the light in normal use This does not affect operation in emergency mode Figure 9 Inverter DALI...

Page 10: ...atherproof Twinspot Weatherproof Pro Twinspot Weatherproof Pro Black Twinspot Weatherproof Ultimate 1 hour 2 hours default 3 hours 4 hours Central battery operation N A N A NON MAINTAINED MAINTAINED MODE 1706 1708 1707 1709 PARTS REPLACEMENTS Twinspot Weatherproof Inverter Twinspot Weatherproof Pro Inverter Twinspot Weatherproof Pro Black Inverter Twinspot Weatherproof Pro Inverter Battery 3000mAh...

Page 11: ... the emergency power breaker or test button in the correct sequence The test interval is fixed and set to 26 weeks 182 days The LEDs indicate the status of the device and which functions are being performed For more information refer to the Configurations Status LEDs and Device Modes document When self test mode is enabled the status LED will flash either 4x switched active detected or 3x switched...

Page 12: ... TWINSPOT PRO Max power TWINSPOT ULTIMATE Max power Viewing distance Mounting type Wiring Battery voltage Charging time Charger operation Charger type N A Surface mounted Hard wired 6 4V 16 hours Multi state Smart charge 220 240V 50Hz 40 C LiFePO4 2 Dependant on jumper IP65 4 5W 7W 10W 22 PRODUCT SPECIFICATIONS TWINSPOT 189mm 321mm 132mm 279mm 129mm ...

Page 13: ...ours to charge its battery Once the battery is fully charged you will need to conduct a manual discharge test as per the requirements of AS NZS 2293 or other relevant standards At the time of printing the Australian standard requires that new fittings operate in emergency mode for at least 2 hours for their first discharge test Further tests are to be carried out at intervals of not more than six ...

Page 14: ...ovided to Evolt with any warranty claim Evolt recommends that the purchaser attaches their proof of purchase to their product manual If you wish to claim under this Warranty you must at your own expense return the product or that part of the product which you believe is defective and proof of original purchase your name address and telephone number and a certificate of installation or other docume...

Page 15: ...9 EN 60598 2 22 1998 A1 2003 A2 2008 EN 55015 2006 A1 2007 A2 2009 EN 61547 2009 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 Luminaires Part 1 General requirements and tests Luminaires Part 2 22 Particular requirements Luminaires for emergency lighting Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Equipment for general l...

Page 16: ...Ph 612 9502 1161 Fax 612 9502 1154 Email sales evolt com au evolt com au Reference 605708_V2 5 ...

Reviews: