26. WARRANTY INFORMATION

Ektor products are distributed in Australia and New Zealand by Evolt Pty Ltd (Evolt). 

The Australian Consumer Law as well as other Australian laws guarantee certain conditions, warranties and 

undertakings, and give you other legal rights, in relation to the quality and fitness for purpose of Ektor products 

sold in Australia. 

In Australia, our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You 

are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable 

loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable 

quality and the failure does not amount to a major failure. What constitutes a major failure is set out in the 

Australian Consumer Law.

Nothing in this Warranty purports to modify or exclude the conditions, warranties and undertakings, and other 

legal rights, under the Australian Competition and Consumer Act and other Australian laws. 

Ektor products are warranted in Australia for a period of 12 months from the date of delivery of the product, 

provided that the products are properly stored, installed, used and maintained in accordance with the instructions 

contained within their manual. 

Products that have been altered in any way or used other than in accordance with their instructions are not 

covered by this Warranty.

This Warranty is not transferable and is valid only in the hands of the purchaser of the product. The warranty 

does not cover Ektor products other than those purchased from Evolt. Proof of purchase must be provided to 

Evolt with any warranty claim. Evolt recommends that the purchaser attaches their proof of purchase to their 

product manual.

If you wish to claim under this Warranty, you must, at your own expense, return the product or that part of 

the product which you believe is defective, and proof of original purchase, your name, address and telephone 

number and a certificate of installation or other document required by the law for the installation of electrical 

products in the place in which the product was installed, to Evolt at the address above within 12 months from the 

date of purchase. Please note that the Warranty does not cover removal or reinstallation of the product or that 

part of the product which you believe is defective.

Evolt’s total liability under this Warranty is limited to the cost of repair or replacement of the faulty product. Evolt 

may satisfy its obligations under this Warranty in full by repair or replacement of a faulty product. 

This Warranty does not apply to consumable items such as lamps or batteries or other items that can be classified 

as consumable. 

For the avoidance of any doubt, any and all warranties or conditions which are not guaranteed under the 

Australian Competition and Consumer Act or the Australian Competition and Consumer Regulations 2010 and 

which are not expressly included in this Warranty as additional warranties or conditions are excluded.

This Warranty does not cover loss or damage caused by wear and tear, misuse, incorrect installation or 

operation, failure to clean and maintain, incorrect voltage or non-authorised electrical connections, adverse 

external conditions (such as power surges and dips, acts of God, exposure to heat, corrosion, insect or vermin 

infestation), use of non-authorised or defective parts or globes, or to items that have been repaired other than by 

Evolt or a repairer approved by Evolt. 

Summary of Contents for 1706

Page 1: ...06 EV TWINSPOT WP 1708 EV TWINSPOT WP PRO 1707 EV TWINSPOT WP PRO B 1709 EV TWINSPOT WP ULTP B 1 Welcome Overview Safety warnings Installation Mounting Range of movement Terminal block wiring Maintaining your Twinspot Replacing the battery Battery life Power and battery charge Wireless daughterboard Self test standard wiring central battery system DALI wiring central battery system Using the inver...

Page 2: ...ttery Smart battery conditioning to ensure the best performance from the battery 450V Electrolytic capacitors which increase the products reliability Highly efficient design to reduce fatigue on the product For buildings requiring longer durations such as 3 4 and 8 hours the installer can change the jumpers found on the unit for automatic scaling of the output Moreover should you require non maint...

Page 3: ... replacement If the product is satisfactory proceed with the installation 2 To mount the Twinspot the cover MUST be removed Remove the cover by unscrewing the cover screws using a large flat blade screwdriver Then pull the cover off as shown below 3 The cover is to be removed for mounting the Twinspot also battery replacement and servicing All installation options can be found in the following sec...

Page 4: ... 3 Mount the Twinspot by fastening screws securely to a flat surface as shown below Use supplied soft washer to waterproof the Twinspot and then put the cover back in place to finish mounting SURFACE MOUNT Figure 2 Surface mount installation Figure 2 Twinspot headlight adjustment 4 M4 cap screw locknut detail 6 RANGE OF MOVEMENT The Twinspots headlight range varies whether it is adjusted horizonta...

Page 5: ...overage of the beam Figure 3 Twinspot headlight horizontal range of movement Centre of rotation Centre of rotation 45 22 5 22 5 45 Figure 4 Twinspot headlight upward range of movement Centre of rotation Headlight tilt max 40 Figure 5 Twinspot headlight downward range of movement Centre of rotation Headlight tilt max 40 ...

Page 6: ...s to release the battery from its mounting position 4 Replace the battery as was previously installed and then secure with cable ties 5 Replace the Twinspot back into its previously mounted ceiling position and ensure the green charge light is illuminated Allow a few minutes for the battery to charge 6 Allow a minimum 24 hours charging time before carrying out any discharge tests as per the requir...

Page 7: ...eded The Ektor Generation III platform uses smart battery charging technology which reduces power consumption and increases battery life During the first stage of operation the battery charger charges the battery until full Afterwards the unit goes into a stage which charges the battery periodically This reduces the battery temperature and reduces the loss of electrolytes which ultimately increase...

Page 8: ...r this part onto the inverter is shown below The inverter can be used in an automatic self test mode which reduces the need for a test switch timer The self test ability automatically disables if the unit is wired to DALI or the wireless daughterboard is attached Additionally the third generation platform can be wired to a central battery system With this wiring the system cannot report the light ...

Page 9: ...ough DALI When used as a central battery system the devices can be tested with DALI A mains rated switch can be wired with this product to turn ON OFF the non emergency light in normal use This does not affect operation in emergency mode A mains rated sensor can be wired with this product to turn ON OFF the light in normal use This does not affect operation in emergency mode Figure 9 Inverter DALI...

Page 10: ...atherproof Twinspot Weatherproof Pro Twinspot Weatherproof Pro Black Twinspot Weatherproof Ultimate 1 hour 2 hours default 3 hours 4 hours Central battery operation N A N A NON MAINTAINED MAINTAINED MODE 1706 1708 1707 1709 PARTS REPLACEMENTS Twinspot Weatherproof Inverter Twinspot Weatherproof Pro Inverter Twinspot Weatherproof Pro Black Inverter Twinspot Weatherproof Pro Inverter Battery 3000mAh...

Page 11: ... the emergency power breaker or test button in the correct sequence The test interval is fixed and set to 26 weeks 182 days The LEDs indicate the status of the device and which functions are being performed For more information refer to the Configurations Status LEDs and Device Modes document When self test mode is enabled the status LED will flash either 4x switched active detected or 3x switched...

Page 12: ... TWINSPOT PRO Max power TWINSPOT ULTIMATE Max power Viewing distance Mounting type Wiring Battery voltage Charging time Charger operation Charger type N A Surface mounted Hard wired 6 4V 16 hours Multi state Smart charge 220 240V 50Hz 40 C LiFePO4 2 Dependant on jumper IP65 4 5W 7W 10W 22 PRODUCT SPECIFICATIONS TWINSPOT 189mm 321mm 132mm 279mm 129mm ...

Page 13: ...ours to charge its battery Once the battery is fully charged you will need to conduct a manual discharge test as per the requirements of AS NZS 2293 or other relevant standards At the time of printing the Australian standard requires that new fittings operate in emergency mode for at least 2 hours for their first discharge test Further tests are to be carried out at intervals of not more than six ...

Page 14: ...ovided to Evolt with any warranty claim Evolt recommends that the purchaser attaches their proof of purchase to their product manual If you wish to claim under this Warranty you must at your own expense return the product or that part of the product which you believe is defective and proof of original purchase your name address and telephone number and a certificate of installation or other docume...

Page 15: ...9 EN 60598 2 22 1998 A1 2003 A2 2008 EN 55015 2006 A1 2007 A2 2009 EN 61547 2009 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 Luminaires Part 1 General requirements and tests Luminaires Part 2 22 Particular requirements Luminaires for emergency lighting Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Equipment for general l...

Page 16: ...Ph 612 9502 1161 Fax 612 9502 1154 Email sales evolt com au evolt com au Reference 605708_V2 5 ...

Reviews: