Product handling on the construction site

Transport

The Self-actuating backflow protectors are 
transported to the construction site with a 
forklift or crane with a lifting fork. To avoid 
damage, they must be lifted, not drag-
ged and never lowered hard against the 
ground.

Reception and inspection 
of the delivery

The Self-actuating backflow protectors is 
inspected immediately when the delivery 
arrives at the workplace. The inspection is 
to check that the delivery corresponds to 
the order and the consignment note. The 
approved delivery is acknowledged on the 
consignment note. Products with defects 
or defects must not be installed. Contact 
the supplier immediately. 

Storage

The storage of materials on the site should 
be planned so that you get the least pos-
sible internal transport. Self-actuating 
backflow protectors must be protected 
against water and always stored in a dry 
place. Furthermore, they must be handled 
so that no mechanical damage occurs to 
them.

Commissioning

The Self-actuating backflow protectors 
must not be put into use until the entire 
installation is in operational condition.

–   Damage due to incorrect transport, 

handling or storage.

–   That the user has failed to inspect, 

maintain and to a reasonable extent 
take care of the equipment.

–   Personal injury or property damage as 

a result of using the product in violation 
of the instructions and specifications in 
this manual.

EKOVENT AB hereby disclaims all responsibility for:

 

EKOVENT:s liability shall be limited to repair 
or replacement of faulty equipment part.

Summary of Contents for EKO-BSV Series

Page 1: ...Installation operating and maintenance instructions 2020 12 Self actuating backflow protector EKO BSV ...

Page 2: ... of manufacture EKOVENT AB Vellinge Certification Product type description Type approval number RISE Certification 1002 EKO BSV SC0800 14 Installation operating and maintenance instructions EKO BSV Product handling 3 General assembly 4 Installation instructions 5 Operation and maintenance 6 ...

Page 3: ...ontact the supplier immediately Storage The storage of materials on the site should be planned so that you get the least pos sible internal transport Self actuating backflow protectors must be protected against water and always stored in a dry place Furthermore they must be handled so that no mechanical damage occurs to them Commissioning The Self actuating backflow protectors must not be put into...

Page 4: ...Mounting can be done horizontally or vertically in a fire cell in a shaft or in a cor ridor in such a way that it can be inspected and cleaned The fire properties are tested according to the same test standard as for CE marked Fire Damper Fire properties corresponding to E90 applies provided that EKO BSV is mounted in a duct outside the fire exposed fire cell applies to both wall and floor When EK...

Page 5: ...h this backflow protection which is why special measures must be taken to solve this Installation of EKO BSV1 2 4 och 5 Textile cone position at 3 m s EKO BSV Textilkon Dim_100 125 EKO BSV Textilkon Dim_160 200 Diameter 100 125 mm Diameter 160 200 mm Distribution duct Possibly Iris damper Air direction EKO BSV Fire seal Fire insulation Fire cell boundary 2 It is important to ensure that the Self a...

Page 6: ...nt EKO BSV Insert in each spiro duct Attach the mounting bracket to the adja cent building part with a suitable dressing Operation Self actuating backflow protector EKO BSV is a type approved protection intended as protection against the spread of smoke in ventilation systems of the fan type in operation EKO BSV closes when a fire occurs in a room and the pressure rises The product is self acting ...

Page 7: ...ck the protective cover and insert Also check that the corrosion protection is intact Check the outer casing of the cover so that it is not damaged Open the 2 locking latches BSV1 and 4 or remove the hatch BSV2 and 5 and then remove the insert Check that the Sealings the insert and the cone are undamaged Check that no objects prevent the cone of textile from closing opening Clean if necessary Put ...

Page 8: ...jselgatan 7 235 32 Vellinge Tel 040 42 16 00 www ekovent se info ekovent se REGIONAL OFFICE GÖTEBORG Boråsvägen 5 435 31 Mölnlycke Tel 031 23 07 40 REGIONAL OFFICE STOCKHOLM Vallgatan 9 170 67 Solna Tel 08 508 613 00 ...

Reviews: