- 2 -
Air Conditioner Component Flushing Unit
EkoFlush-K570
OPERATING MANUAL
1. Table of contents
Par. 2. Safety Precautions
2
3. Unit Description
3
4. Accessories
4
5. Technical Specifications
5
6. Main principles and interconnection
5
7. Flushing Procedure
6
8. Controlling
8
9. Completing Flushing
10
10. Exchange of SOLSTICE
®
PF-C solvent
11
11. Oil Change, Adding Oil
11
12. Waste Disposal
12
13. Risks Analysis
12
14. Failures, Possible Causes, Troubleshooting Guide
13
15. Flow Diagram
15
16. Block Flowchart
16
17. List of Replacement Parts
17
18. Components
18
19. CE Conformity Declaration, Certificate Electrotechnical Testing Institute
19
20. Safety guidelines
20
21. Warranty and disposal
21
The EkoFlush-K570 device is designed for qualified servicemen in the refrigeration branch!
2. Safety Precautions
WARNING: Failure to follow these precautions can result in serious injury.
•
This Operating Manual is to be read and understood completely before operating this Unit.
•
Suitable skin and eye protective equipment should be worn while operating or maintaining this Unit.
•
The use of flushing solvent is permitted only in cylinders equipped with a safety valve. Cylinders
can be filled up to a maximum of 70% of the available volume. Before beginning the flushing
procedure, please check the availability of the solvent by putting the cylinder on a scale.
•
The flushing agent must be drained every time before transporting this Unit (“0” bar or less should
be shown on the low-pressure manometer).
•
The EkoFlush-K570 unit can only be transported by transportation means if its refrigerant cylinder
is disassembled and transported separately. The main unit can be transported in the standard
position on wheels (properly protected against moving), or laid down on its rear side leaning on its
handle and wheels. Other positions are prohibited.
•
The Unit must be protected against open flames and flying sparks.
•
All repairs must be done by an authorized service or by the Unit producer.
•
This Unit can be used only in compliance with EU regulations on manipulation of volatile matters.
•
Material Safety Data Sheet
must be according to the regulations located in the workshop. The
English version can be found on the website
CAUTION
Failure to observe precautions as outlined in this Operating Manual can result in damage to the
compressor, other components or even of the Unit as a whole, and cannot be supported or covered by
the guarantee.
Summary of Contents for EkoFlush-K570
Page 1: ......
Page 18: ... 18 18 Components ...
Page 19: ... 19 19 CE Conformity Declaration ...
Page 21: ......