![EKOM DK50 DS User Manual Download Page 19](http://html.mh-extra.com/html/ekom/dk50-ds/dk50-ds_user-manual_2374216019.webp)
MAINTENANCE
18
NP-DK50 DS-23_08-2018
26
•
Unscrew the cover and pull it out using the enclosed wrench (26).
•
Unscrew the filter holder.
•
Replace the filter and screw the filter holder
into place.
•
Screw the cover back in place.
Spare filtration pads:
Bronze (40 μm) (19a) AF20P-060S-7-40B
Item 025200142-000
Plastic (5 μm) (19b) AF20P-060S
Item 025200113-000
If the water release system becomes clogged, disassemble the release valve
(f), clean the outlet, remove the float (b) with a lever mechanism (c, d, and e)
from the tank, clean all components with a soap solution and then
reassemble.
Setting outlet air pressure
To unlock the control button of the
regulator (20), raise it slightly and rotate
it to set the demand outlet pressure.
After setting the pressure, lock the
control button of the regulator by
pushing it down.
Cleaning the pressure regulator
•
Set the pressure to the minimum position
•
Remove the plug (1)
•
Rotate and remove the latch (2)
•
Remove the line from the valve (3) and
the valve (4), then clean the valve seat
and the o-ring
•
Re-install
the
components
in
the
following order: (4), (3), (2) and (1)