SERVICE MANUAL
SM-eVENT-GB-3_8-2006.doc
9
5.5.
First putting into operation
•
Check whether all fixing screws used during transport were removed.
•
Check that the connections of the compressed air supplies are correct.
•
Check for proper connection to the mains supply.
•
Switch on the pressure switch (6) to position “I”.
After first putting the compressor into operation, the air chamber of compressor is pressurized to a
‘switching-off’ pressure and the compressor will then be automatically switched off. During the
following time period the compressor works in an automatic mode, i.e. according to the
consumption of compressed air, the compressor is switched on and off by the pressure switch.
During the operation, the appliance releases condensed water from the condenser (filter)
automatically to the evaporative tray (20).
5.6.
Additive accessory
•
Tube for supporting equipment
is suitable for gripping of respiratory apparatus with accessories. Please remove the plug in the
middle of the upper side before installation. Screw the tube into the socket and tighten it fast.
Technical data:
diameter
25 mm
height
1100 mm above the floor
Max. tube loading accepted is 18 kg. The centre of gravidity of supporting
equipment must be in the axis of the tube, max. 1100 mm above the floor. Other
connecting consult with manufacturer. Producer recommends an supporting
equipment disassemble before transport .
6. PERSONNEL (SEE ANNEX)
In the case of danger, switch the appliance off at the switch and pull out the
mains plug.
Automatic operation. When the pressure in pressure tank falls down to a ‘switch on’
pressure, the compressor is automatically switched on. The compressor is automatically
switched off when the pressure increases to the ‘switching off’ pressure in the pressure
tank.
6.1.
Switch on compressor
The compressor is switched on by mains switch (6) by putting it to position „I“. Switching on of the
compressor is signaled by the green indicator (4).
6.2.
Running on compressor
When the pressure of the air at the ‘Inlet’ port is reduced or if there is a reduction of pressure in
the air chamber, the compressor is switched on and the air chamber is filled with compressed air.
After the ‘switching-off’ pressure is reached, the compressor is automatically switched off.
Pressure of the output air from compressor indicates the manometer (1).
During the operation of the compressor, the pointer of the humidity indicator (2), should be in the
green zone. If the consumption of air from an appliance is larger that the maximal outflow, the
PDF created with pdfFactory trial version