PRODUCT MAINTENANCE
NP-DK50-Nx2VTM-AD-EN-6_04-2022
52
04/2022
Fig. 31: Solenoid valve replacement
Solenoid valve assembly
Replacement solenoid valves are delivered as
disassembled replacement parts. The new
valve must be assembled before a solenoid
valve is replaced.
Mount the valve coil (4-5) onto the
valve body (4-4) and secure with the
nut (4-6).
Insert the valve membrane spring (4-
3) into the membrane (4-2) and the
insert into the assembled valve coil
and body assembly.
Then mount the valve seal (4-1) onto
the dryer body.
Fig. 32: Solenoid valve assembly