TECHNICAL DATA
06/2022
15
NP-DK50 3x4VR_M-AD-A-EN-3_06-2022
TECHNICAL DATA
Compressors are designed for operation in dry, ventilated and dust-free indoor rooms under the
following climactic conditions:
Temperature
+5°C to +40°C
Relative humidity
max. 70%
Working pressure 6
– 8 bar
DK50 3x4VR/M
Nominal voltage, Frequency
a)
V, Hz
3x400, 50
Capacity at 6 bar (FAD) -2
0°C
l/min
680
Working pressure
b)
bar
6.0
– 8.0
Rated current
A
15.9
Main circuit protection device rating
A
16
Main electrical feeder
mm
2
5C x 1.5
Enclosure
IP10
Motor power
kW
3x2.2
Air tank volume
l
290
Maximum operating pressure of safety valve
bar
10.0
Noise level at 5 bar (L
pA
)
dB
≤80
Operating mode
%
S1-100
PDP drying performance at 7 bar
d)
°C
-20
Time to fill air tank from 0 to 7 bar
s
230
Required cooling air changes in space
m
3
/h
1850
Dimensions (net)
w x d x h
mm
2520x800x1025
Dimensions
– compressor
w x d x h
mm
1780x800x1025
Dimensions
– AD750E dryer
w x d x h
mm
530x350x965
Net weight
c)
kg
327
Net weight
– compressor
c)
kg
283
Net weight - dryer
c)
kg
44
a)
Specify the compressor version when ordering
b)
Consult any other range of pressure with the supplier
c)
Weight is indicative and only applies to the product without accessories
d)
Applies to ambient temperatures of <30°C PDP – pressure dew point
Summary of Contents for DK50 3x4VR/M
Page 1: ...DK50 3x4VR M User manual ...
Page 2: ......
Page 13: ...PRODUCT DESCRIPTION 06 2022 13 NP DK50 3x4VR_M AD A EN 3_06 2022 Fig 2 Adsorption dryer ...
Page 14: ...PRODUCT DESCRIPTION NP DK50 3x4VR_M AD A EN 3_06 2022 14 06 2022 Fig 3 Switchboard ...
Page 30: ...INSTALLATION NP DK50 3x4VR_M AD A EN 3_06 2022 30 06 2022 14 PNEUMATIC DIAGRAM DK50 3x4VR M ...
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......