background image

It is important that the following clearances are maintained from the appliance to combustible materials and are dependant on the desired

mounting location as defined below.

This appliance is designed to be wall mounted only. Do not stand it on the floor.

The minimum distance from the top of the appliance to a ceiling is 500mm. 

The minimum distance from the bottom of the appliance to the floor is 100mm.

The minimum distance to the sides of the appliance is 100mm.

The minimum distance to the front of the appliance is 500mm.

4.0 SITE REQUIREMENTS 

5.0 CLEARANCES TO COMBUSTIBLE MATERIALS

©

2016 Focal Point Fires plc.

3

3.0 ELECTRICAL INSTALLATION REQUIREMENTS

• DO NOT run the mains cable under carpets, rugs etc.

• DO NOT cover or obstruct the heater in any way. Overheating will result if it is acci-

dentally covered.

• Never immerse the product in water or any other liquids.

• DO NOT use the appliance outdoors.

• Before cleaning the appliance, ensure it is unplugged from the power and that it is com-

pletely cool.

• DO NOT clean the appliance with abrasive chemicals.

• Never use accessories that are not recommended or supplied by the manufacturer. It

could cause danger to the user or damage to the appliance.

• DO NOT insert or allow foreign objects to enter the inlet or outlet vents as this may

result in electric shock, fire or damage to the appliance.

• DO NOT install the fire using an extension cord.

• Unplug from the mains supply if the appliance is not to be used for long periods.

The appliance is designed to be wall mounted via the wall mounting plate and fixings provided. The wall should be relatively flat and not inter-

fere with any of the ventilation slots in the appliance casing. 

The wall must be structurally sound and of a material capable of withstanding moderate heat. Finished plaster, conventional wallpaper, dry-lined

plaster board are examples of suitable materials. Materials such as “flock” blown vinyl”, embossed paper and cloth wall coverings which are sen-

sitive to even small amounts of heat should be avoided, as some discolouration may occur. It should be noted that the appliance creates warm

convected air currents. These currents move heat from the room surroundings to, and up the wall surfaces adjacent to the heater. 

Installing the heater next to these types of wall coverings or operating the heater where impurities in the air, (such as tobacco smoke) exist,

may slightly discolour wall finishing.

If the appliance is to be mounted on a dry lined or timber framed construction then the integrity and ability of the wall to carry the weight of

the appliance must be confirmed. It is important in these circumstances that any vapour barrier and/or structural members of the house frame

are not damaged.  If you are unsure of the ability of the wall to carry the weight and/or which type of wall fixing to use, you should take pro-

fessional advice and obtain the correct fixings. Alternatively, find a more suitable wall location.

DO NOT

-

mount on a ceiling or floor.

-

recess any part of the appliance into the wall.

-

site any electrical equipment e.g. plasma screen TV sets etc, 

on the wall above the appliance. 

site in a position where curtains or drapes could cover the appliance.

-

site in a position where other soft materials could cover e.g. below a coat rack.

-

site behind an opening door where mechanical impact/damage could occur.

-

site where the supply cable would become a trip hazard.

-

sit, stand or forcefully pull on the appliance.

-

obstruct, cover or force items into the openings.

-

use the heater to dry clothes.

site/use in an outdoor location(s).

-

run the supply cable under carpets.

2.0 APPLIANCE DATA

Weight (kg):

17.0 kg

Supply Cord:

2 metres

Dimensions (mm):

H 466 x W 757 x D 100

Fuse:

13Amp

Supply Voltage and rating power: 220-240V a.c. 50/60Hz, 1716 - 2016

Location:

Indoor Use

Heating Elements:

2 x 900/1000Watts (1.8 - 2.0kW)

LCD Display:

16 Watts

DO NOT RECESS ANY PART OF THE APPLIANCE.

The appliance is supplied with a pre-wired three pin plug (13 Amp fuse rated), and 2 metre cable. A standard switched outlet/wall socket, (includ-

ing earth provision), must therefore be located within this distance, and be easily accessible in order to isolate the supply for maintenance and

cleaning.  This socket must not be mounted behind or above the appliance.   

IMPORTANT: THIS APPLIANCE MUST BE EARTHED.

1.0 PRELIMINARY NOTES - CONTINUED

GB IE

Summary of Contents for SE2015

Page 1: ...y Focal Point Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc 1 Revision F 02 16 2016 Focal Point Fires plc GB IE WAL...

Page 2: ...rning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision...

Page 3: ...ld be noted that the appliance creates warm convected air currents These currents move heat from the room surroundings to and up the wall surfaces adjacent to the heater Installing the heater next to...

Page 4: ...den members of the wall using two of the fixing screws provided If this is not achievable then the wall should be strengthened using appropriate building materials If there is no alternative than to r...

Page 5: ...scene Fig 8 Gas fire medium Fig 9 Gas fire high Fig 10 Gas fire Blue Flame Fig 5 Log fire Fig 6 Twig fire Fig 7 Coal fire Scene select buttons Volume and mute buttons Figure 14 LCD on off control Con...

Page 6: ...ith an N or coloured black The brown wire must be connected to the terminal marked with an L or coloured red The green yellow wire must be connected to the earth terminal which is marked with an E or...

Page 7: ...hird party who undertakes any work carried on the product or fits parts unless we have approved such work in advance of it being carried out The guarantee period will not be extended even if we repair...

Reviews: